3590
Reference Code
Description/Action Perform all actions before exchanging Failing Items
9800 to 9803
I/O processor successfully recovered from temporary error
No action required. This reference code is logged for information only.
9810
Problem analysis has determined a part should be replaced.
This reference code is used for ending Online Problem Analysis with a list
of failing items. (Information Only)
9899
Problem analysis completed, the problem has been corrected.
This reference code is used for ending Online Problem Analysis when no
problem was found or the problem was corrected.
9900
Licensed Internal Code for tape unit was not upgraded
The I/O processor loading of Licensed Internal Code (LIC) to the
programmable tape unit was not completed.
The tape unit will continue to operate with the previous LIC. You may do
either of the following:
v Wait for next IPL when the system will attempt to load the LIC for the
tape unit again.
v Perform "TU-PIP4" on page 453 to reset the IOP and the tape unit. When
the IOP is reset, if the device has the wrong level of LIC, the IOP will
attempt to load the new LIC.
FFF6
Tape volume statistics logged (no action required)

Tape Unit Failing Items

Notes:
1. To determine the failing items, go to "Failing Items" on page 479.
2. To determine the associated part numbers, go to "Type, Model, and Part
3. To determine the parts associated with symbolic FRUs, such as "ANYBUS", or
Failing Item
Description
05H3834
Interposer
61G8324
Terminating plug
ANYFC
Any Fibre Channel device
EXTSCSI
External signal cable
FCCABLE
Fibre Channel cable
FCCODE
Gateway device Licensed Internal Code
FCDEV
Fibre Channel device
FCGATE
Gateway device
FCIOA
Fibre Channel IOA
MHQTMED
Defective removable media
UHQCLN
Tape unit needs cleaning
UHQCNFG
Tape configuration detected by I/O processor;
not valid
150
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Number list" on page 885.
"DEVTERM", go to "Symbolic FRUs" on page 495.
Document Description
IBM 3590 Tape Drive Service Guide
IBM 3590 Tape Drive Service Guide
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
IBM SAN Data Gateway Service Guide
Problem Analysis; Symbolic FRU Isolation
Magnetic tape subsystem service information
Magnetic tape subsystem operator's information
Installation
Failing Item
UHQFIXD

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents