LIC PIPs
5. Move the load-source disk unit to the load-source MSIOP.
001C: The disk units that are needed to update the system configuration are
missing.
Perform an IPL by doing the following:
1. Select Manual mode on the control panel.
2. Perform an IPL (see "Initial Program Load (IPL) Information" in the iSeries
This ends the procedure.
001D:
1. Is the Disk Configuration Warning Report displayed?
2. Select option 5 on the Bad Load Source Configuration message line. Press Enter to
This ends the procedure.
001E: The load-source data must be restored.
Go to "Disk Service Support" on page 893.
This ends the procedure.
001F: Licensed Internal Code was installed on the wrong disk unit of the
load-source mirrored pair.
The system performed an IPL on a load source that may not contain the same level
of Licensed Internal Code that was installed on the other load source. The type,
model, and address of the active device are displayed in words 4-7 of the SRC.
If the load-source disk unit in position 1 contains the correct level of Licensed
Internal Code, perform the following:
1. Select Manual mode and perform an IPL to DST (see "Dedicated Service Tools
2. Is the Disk Configuration Warning Report displayed?
360
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
No
Yes
Go to "Recover Remote Load Source" on page 917.
This ends the procedure.
Service Functions information) to determine the cause of the problem.
Yes
No
Ask your next level of support for assistance.
This ends the procedure.
rebuild the load-source configuration information.
If there are other types of warnings, select option 5 on the warnings and correct
the problem.
(DST)" in the iSeries Service Functions information).
Yes
No
The system is now using the correct load source.
This ends the procedure.