Twinaxial Workstation PIPs
8. Ensure that the following conditions are met:
9. Perform the following:
10. Does the same reference code appear on the control panel?
11. Is the reference code one of the following?: 0001, 0003, 0004, 0005, 0006, 0101,
12. Does the system have an alternative console on a second workstation IOP?
13. There is either a Licensed Internal Code problem, or there are two device
468
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
e. If no reference code appears, repeat steps a through d of this step
until you have checked all devices disconnected previously.
Continue to perform the initial program load (IPL).
This ends the procedure.
v The workstation addresses of all workstations on the failing port must be
correct.
Each workstation on the port must have a separate address, from 0 through
6. See the workstation service information if you need help with checking
addresses.
Did you find a problem with any of the above conditions?
Yes
No
Go to step 11 of this procedure.
a. Correct the problem.
b. Select function 21 (Make DST Available).
c. Check the console and any alternative consoles for a display.
Does a display appear on any of the consoles?
No
Yes
Continue to perform the IPL.
This ends the procedure.
Yes
No
Go to "Starting Point for All Problems" on page 4 for this new
problem.
This ends the procedure.
0103, 0104, 0105, 0106, 5004, 5082, B000, D010, or D023.
No
Yes
Go to step 15 of this procedure.
Yes
No
Go to step 14 of this procedure.
failures on the workstation IOPs, consoles, or cables. The console and any
alternative consoles are the most probable causes for this failure.
v See the service information for the failing display to attempt to correct the
problem. If a display is connected to the system by a link protocol
converter, use the link protocol converter information to attempt to correct
the problem. The link protocol converter may be the failing item.
v If you have another working display, you can exchange the console and
alternative consoles and perform an IPL to attempt to correct the problem.