IBM i 830 Repair Manual page 121

Table of Contents

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
8610
Air Moving Device B01 Not Present
8620
Air Moving Device B02 Not Present
8810
Battery Power Unit missing
8811
Battery Charger Unit missing
8910
External Netfinity Server 3.3V fault
8920
External Netfinity Server Power Good fault
8930
Integrated Netfinity Adapter fault
8940 to 8943
External Netfinity Server R485 Communication fault
9012
Address not valid.
LIC command had a frame address that was not valid.
Exchange the SPCN frame-to-frame cables to the failing frame.
9013
Invalid Node Address.
The address in the SPCN command does not match the secondary nodes
assigned address.
Exchange the failing items for the SPCN node reporting the error.
9014
A command has an invalid address mode.
A command from the system unit specified a unit address of D or E or had
a frame address of 00.
Exchange the failing items in the system unit.
9016, 9021
A command to an SPCN node was rejected.
No action required. This reference code is logged for information only.
9022
Addressed Unit not in frame.
The addressed unit does not exist in the addressed frame.
No action required. This reference code is logged for information only.
9023
Addressed Unit exists, but the frame is powered off.
The addressed unit is in a frame that is powered off.
No action required. This reference code is logged for information only.
9024
SPCN Licensed Internal Code not valid.
The Licensed Internal Code in one of the secondary nodes is not valid. The
code will be reloaded.
No action required. This reference code is logged for error analysis only.
Failing Item
AIRMOVR
TWRCARD
AIRMOVR
TWRCARD
BATRY
BATCHGR
ALTMANL
TWRCARD
TWRCARD
ALTMANL
TWRCARD
TWRCARD
CBLALL
ALTMANL
TWRCARD
CBLALL
TWRCARD
CBLALL
AJDG301
TWRCARD
Chapter 2. Unit Reference Codes