Data Recovery and General System Information
11. Is the customer data recoverable (see step 3 of this procedure)?
12. Perform an IPL from removable media and select the option to install
13. Did you get a Disk Configuration Error Report with a "Unit has incorrect
14. Restore the customer data from the tape to the new disk unit by doing the
906
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
f. Select the disk unit that you want the data restored to on the Restore Disk
Unit Data display.
g. Press F10 to confirm the restore.
The Function Status display shows the percent of customer data restored.
The system will IPL to the Use Dedicated Service Tools (DST) display when
the restore has completed.
Note: Any damaged objects that were restored must be loaded again by
the customer (have the customer see the Backup and Recovery
information).
The system is ready for the next IPL.
This ends the procedure.
Yes
No
Go to step 15 of this procedure.
Licensed Internal Code and restore disk unit data. (See "Installing Licensed
Internal Code" in the iSeries Service Functions information, which performs an
IPL and installs the Licensed Internal Code.)
logical partition configuration" warning?
No
Yes
You have logical partitions that need to be recovered before you can
continue with this disk unit recovery procedure. Perform the
following:
a. Enter the Use Dedicated Service Tools (DST) option from the IPL
or Install the System display.
b. Enter the password 22222222.
Note: If this password is not valid, ask the customer for the
correct password.
c. Select the Work with system partitions option on the Use
Dedicated Service Tools (DST) display.
d. Select the Recover configuration data option on the Work with
System Partitions display.
e. Select the Recover primary partition configuration data on the
Recover Configuration Data display.
f. Review the information on the Select Disk Unit for Configuration
Data Recovery display. Select the disk unit with the most recent
date and correct system serial number and press enter. The system
automatically copies the configuration data to the primary
partition's load source, and performs an IPL.
Continue with the next step of this procedure.
following:
a. Enter the Use Dedicated Service Tools (DST) option from the IPL or Install
the System display.
b. Enter the password 22222222.

Hide quick links: