Table 41. FRU Locations and Failing Components Table for Models 830, SB2 System Unit with FC 9074 Base I/O
Position
FRU Name
M06
Network
Interface
Controller
(NIC) Card
M06 Ports
Network
Interface
Controller
(NIC) Ports
M06A
Clock Card
M06-C08
HSL Ribbon
Cable
PP1
PP2
Power Supply
BP1
BP2
AMD
C01
PCI Card
C02
PCI Card
C03
PCI Card
C04
PCI Card
C05
PCI card
C06
PCI Card (if no
IXS in C05)
C07
PCI Card
Tower (continued)
Possible Failing
Type, CCIN, or Part Number
Component
(use the "Type, Model, and
Part Number list" on page 885
to determine the part number
Network Interface
Controller (NIC)
See Figure 32 on
page 716.
Clock Card
HSL connection
(SIGC73), See "Model
830 and Model SB2 with
FC 9074" on page 780.
Power Supply
AMD
IOP
The failing component is
either an:
1. 2842 or 2843
1. IOP
2. See "Type, Model, and Part
2. IOA
.
The failing component is
either an:
1. 2842 or 2843
1. IOP
2. See "Type, Model, and Part
2. IOA
The failing component is
either an:
1. 2842 or 2843
1. IOP
2. See "Type, Model, and Part
2. IOA
The failing component is
either an:
1. 2842 or 2843
1. IOP
2. 2890
2. Integrated xSeries
Server (IXS)
The failing component is
either an:
1. 2842 or 2843
1. IOP
2. See "Type, Model, and Part
2. IOA
IOA
See "Type, Model, and Part
when Type or CCIN are
given.)
2732, 2754, 2758, or 2769
N/A
25AB, 25AD
See Table 54 on page 781.
515B
04N3345
2842 or 2843
Number list" on page 885.
Number list" on page 885.
Number list" on page 885.
Note: When the IXS card
is installed in this position
concurrent maintenance at
the card position is not
recommended.
Number list" on page 885.
Number list" on page 885.
Chapter 5. Locations, Addresses, and Part Listings
Locations and Addresses
Removal and Installation/Recovery
Procedure
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
N/A
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
N/A
Go to "Models 830/SB2 with FC 9074
– Power Supply (PP1 and PP2)" on
page 670.
Go to "Models 830/SB2 with FC 9074
– AMD (BP1 and BP2)" on page 654
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
Go to "Models 830/SB2 with FC 9074
– Cards – Dedicated" on page 658.
If IXS, go to "Models 830/SB2 with
FC 9074 – Cards – Dedicated" on
page 658. Otherwise, go to "Models
830/SB2 with FC 9074 – Cards –
Concurrent" on page 655.
Go to "Models 830/SB2 with FC 9074
– Cards – Concurrent" on page 655.
Go to "Models 830/SB2 with FC 9074
– Cards – Concurrent" on page 655.
711