Table of Contents

Advertisement

This ends the procedure.

BUSPWR

There is a problem with the +29V Bus.
Attention: AC power must be removed from the system before removing or
installing regulator 3.
Perform the following:
1. Is the SRC 1xxx 1200 displayed?
Yes
No
Go to "Starting Point for All Problems" on page 4.
2. Perform the following:
a. Remove regulators R01 to R10 (except R3) R11 and R20 from the system
unit.
b. Power on the system.
Is the SRC 1xxx 1200 displayed?
Yes
No
Go to step 15 on page 511 of this procedure.
3. Perform the following:
a. Remove one of the AMDs from the system not previously removed during
this procedure.
b. Power on the system.
Is the SRC 1xxx 1200 displayed?
Yes
No
The AMD you removed in this step is the failing item.
This ends the procedure.
4. Have you removed all of the AMDs one at a time?
No
Yes
Install all AMDs and go to step 6 of this procedure.
5. Perform the following:
a. Install the AMD that was removed in step 3 of this procedure.
b. Go to step 3 of this procedure.
6. Perform the following:
a. Power off the system.
b. Remove the battery power unit charger.
c. Power on the system.
Is the SRC 1xxx 1200 displayed?
Yes
No
The battery power unit charger that you removed in this step is the
failing item.
This ends the procedure.
7. Perform the following:
a. Remove all except one of the bulk power supplies from the system.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Symbolic FRUs
509