Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI01141
FI01141 indicates that a loss of power to an IOP, to an internal device, or to an external
device may have occurred.
1. Are 0000 xxxx, 1xxx xxxx, or A6xx 698x SRCs displayed on the control panel?
2. Did the SRC that directed you to this FI code involve an externally attached device or
3. The power supply cables or connections to internal disk units, tape units, diskette units,
FI01201
FI01201, FI01202, and FI01203 indicates that the disk drive and logic card is the failing item.
Find the disk unit type number in the "Type, Model, and Part Number list" on page 885 to
determine the part number.
FI01202
See FI01201.
FI01203
See FI01201.
FI02092
See FI00092.
FI02112
FI02112 indicates that the addressed storage device is the failing item.
Perform the following:
1. Is the device location information available in the Service Action Log?
2. Find the IOP address and the device address (see "SRC Address Formats" on page 936).
3. To determine the location of the I/O processor card, see "Locations and Addresses" on
4. Exchange the failing device. Use the device type to determine the part.

Symbolic FRUs

ACMODUL

An AC module may be failing.
Perform the following to determine the part number for the failing AC module:
1. Is SRC 1xxx 00AC displayed?
No
Yes
Go to "Chapter 2. Unit Reference Codes" on page 59 and use the SRC
displayed on the control panel.
an IOP with an externally attached device?
No
Yes
Verify that there is no obvious problem with power to the device. If you
suspect a power problem with the device, go to the service information for that
external device.
or optical storage units may be the failing item.
v For cable information, see "Power and Signal Cables" on page 779.
v For part numbers, see "Part Assemblies" on page 802.
No
Yes
Exchange the failing item. See "Recovery Procedures" on page 893.
Note: If the failing item is in a migration tower, go to the recovery procedures
in the Migrated Expansion Tower Problem Analysis, Repair and Parts.
This ends the procedure.
page 705 and find the diagram of the system unit or the expansion unit. Then, find:
v The IOP card location identified by the direct select address.
v The addressed storage device location identified by the device address.