Symbolic FRUs
This ends the procedure.

PLUS

The list of possible failing items that are displayed on-line is not complete. There is
not enough space to display all of the failing items. See the complete list of
possible failing items in the appropriate unit reference code table in "Chapter 2.
Unit Reference Codes" on page 59.
This ends the procedure.

PPCIMIN

PPCIMIN: Primary PCI bus in an I/O expansion tower.
The failing component is the Tower Card in an FC 5075 expansion tower.
1. If you are working from the Service Action Log and a card position is listed
566
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Table 27. (continued)
System
Name of
Model,
FRU to
Tower,
Exchange
Expansion
Unit, or
Machine
Type
Models 830
PCI IOP or
and SB2 base
IOA
I/O tower
(FC 9074)
Models 840
PCI IOP or
and SB3 base
IOA
I/O tower
(FC 9079)
External
Integrated
xSeries
xSeries
Server
Adapter
Card
with this failing component, then that is where the error is located, continue
with the next step in this procedure. Otherwise, record the bus number value,
BBBB, in word 7 of the SRC. See "Breaking Down The SRC" on page 280 for
help in determining the bus number. Search for the bus number in HSM or the
System Configuration Listing to determine which FC 5075 I/O tower contains
the failing component.
FRU
Link to Location
Position
Diagram
C01 - C07
"Locations —
C09 - C15
Models 830, SB2
System Unit with FC
9074 Base I/O
Tower" on page 709.
C01 - C07
Figure 36 on
C09 - C15
page 724.
Follow the
Go to "Locations —
HSL cables.
Integrated xSeries
Adapter Card (IXA),
Formerly the
Adapter for
Netfinity Server" on
page 748.
Link to Failing
Component Service
Information. (CCIN,
PN, Removal and
Installation Procedure)
Table 41 on page 710.
Table 43 on page 725.
Go to Table 47 on
page 749.

Hide quick links: