6. Go to "Hexadecimal Product Activity Log Data" in the iSeries Service Functions
book to obtain the address information. When that procedure instructs you to
return to the previous procedure, return to step 8 of this procedure.
7. Addressing information is in the Bus-Bus-Bus-Bus/Card-card/board-board
(BBBBCcbb) format as follows:
v If characters 7 and 8 of the top 16 character line of function 12 (word 2) are
60:
– The IOP address is characters 1-8 of the bottom 16 character line of
function 12 (word 4) in the format "BBBBCcbb".
– The device address is characters 9-16 of the bottom 16 character line of
function 12 (word 5) in the format "abcd efgh".
v If characters 7 and 8 of the top 16 character line of function 12 (word 2) are
13, 17, 27, or 29:
– The IOP address is characters 9-16 of the top 16 character line of function
12 (word 3) in the format "BBBBCcbb".
– The device address is characters 1-8 of the bottom 16 character line of
function 12 (word 4) in the format "abcd efgh".
v If characters 7 and 8 of the top 16 character line of function 12 (word 2) are
62:
– The IOP address may be characters 9-16 of the top 16 character line of
function 13 (word 7) in the format "BBBBCcbb".
– The device address may be characters 1-8 of the top 16 character line of
function 13 (word 6) in the format "abcd efgh".
8. The BBBBCcbb format is the hexadecimal direct select address of a card
location in the system unit. The format definition is:
BBBB—System Bus
Cc—System Card
bb—System Board
9. Go to step 12 of this procedure for IOA and device address information.
10. Addressing information is in the Bus/Board/Card format.
Note: This format shows the system bus number in decimal form.
If no address information is available in the console error message, check the
product activity log entry that is associated with the console error message.
Figure 62 on page 938 is an example of a product activity log display for a
storage device. Other devices (for example, workstations or communications)
have similar displays. For more information about the product activity log, see
"Product Activity Log" in iSeries Service Functions.
Chapter 6. Data Recovery Procedures and General System Information