(432X, 660X, 671X, 673X) Disk Unit Reference Codes - IBM i 830 Repair Manual

Table of Contents

Advertisement

(432x, 660x, 671x, 673x) Disk Unit Reference Codes

1. If the error is reported on the control panel, the unit reference code is
2. Find the unit reference code in the following table.
Notes:
1. If the failing item is a failing item (FI) code, go to "Failing Items" on page 479
2. If the failing item is a type number, go to "Type, Model, and Part Number list"
3. If the failing item is a symbolic FRU, go to "Symbolic FRUs" on page 495 to
4. The 673x is a read cache. Perform all actions required for 673x as a disk drive
Reference Code
Description/Action Perform all actions before exchanging Failing Items
102E
Out of alternate sectors for disk storage
3002
Addressed device failed to respond to selection
3010
Disk device returned wrong response to IOP
3020
Storage subsystem configuration error
If an MES is being installed, verify the configuration.
3029
A device replacement has occurred
No action required. This reference code is logged for information only.
characters 5 through 8 of the top 16 character line of function 11. If the error is
reported on the console, the unit reference code is the 4 rightmost characters of
word 1.
If the failing item is a disk unit, go to Start Disk Service Here in "Recovery
Procedures" on page 893.
to determine which part number associated with the FI code is failing.
on page 885 to determine the part number.
determine the part number.
and logic card except where separate 673x cache instructions are provided.
432x, 660x, 671x, 673x
Failing Item
DISKDRV
DISKDRV
DISKTRY
FI01112
BACKPLN
FI01106
FI01140
FI01141
DEVTERM
DISKDRV
DISKTRY
BACKPLN
FI01112
FI01141
FI01140
DEVTERM
DISKDRV
DISKTRY
FI01106
FI01112
BACKPLN
FI01141
FI01140
DEVTERM
Chapter 2. Unit Reference Codes
151

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents