Locations and Addresses
772
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Table 50. IOP, IOA, and device address information for FC 5074 I/O Tower (continued)
Position
Possible Failing Item DSA (BBBBCcbb)
D21
Disk Unit
D22
Disk Unit
D23
Disk Unit
D24
Disk Unit
D25
Disk Unit
Unit Address
Note: IOA and
device DSA's will not
follow the rules
below if the IOA is
manually reassigned
after IPL.
The disk unit has the
x20300FF (where x is
same DSA as the IOA
the same as the first
attached to the
character of the
internal cable
xFFFFFFF IOA Unit
labelled "L-1".
Address)
x20400FF (where x is
the same as the first
character of the
xFFFFFFF IOA Unit
Address)
x20500FF (where x is
the same as the first
character of the
xFFFFFFF IOA Unit
Address)
x20600FF (where x is
the same as the first
character of the
xFFFFFFF IOA Unit
Address)
x20700FF (where x is
the same as the first
character of the
xFFFFFFF IOA Unit
Address)