Symbolic FRUs
13. Perform the following:
14. Perform the following:
15. Perform the following:
16. Have you installed all of the units removed in step 10 on page 611 of this
17. This ends the procedure.
18. Is the SRC 1xxx 840C?
19. Is the SRC 1xxx 8413?
612
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
↓
The control panel you replaced in this step is the failing item.
This ends the procedure.
a. Power off the system.
b. Exchange the SPCN card in the system unit (TWRCARD).
c. Power on the system.
Does the SRC 1xxx 840B appear on the panel?
Yes
No
↓
The TWRCARD card you replaced in this step is the failing item.
This ends the procedure.
a. Power off the system.
b. Exchange the backplane in the system unit.
c. Install all parts that were removed.
This ends the procedure.
a. Power off the system.
b. Install one of the units removed in step 10 on page 611 of this procedure.
c. Power on the system.
Does the SRC 1xxx 840B appear on the panel?
No
Yes
↓
The last unit you installed in this step is the failing item.
This ends the procedure.
procedure?
Yes
No
↓
Repeat step 15 of this procedure.
No
Yes
↓
The memory module has been mis-plugged, reinstall the correct
memory module and check to see that it is seated correctly.
If a problem still exists exchange the following part:
v Memory Module (See symbolic FRU "CCIN" on page 515 for the
correct part.)
This ends the procedure.
No
Yes
↓
Exchange Processor 1 (See symbolic FRU "CCIN" on page 515 for the
correct part.)
This ends the procedure.