IBM i 830 Repair Manual page 495

Table of Contents

Advertisement

Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI00096
FI00096 indicates that the IOP attached to the load-source device is the failing item.
Note: Determine if the system has logical partitions. Go to "Determining if the System Has
Logical Partitions" on page 943, before continuing with this procedure.
1. Verify that the IPL type is correct:
2. The failing CFIOP or IOP may have a removable storage I/O adapter FRU. Replace the
FI00098
FI00098 indicates that the load-source disk device is the failing item.
Note: Determine if the system has logical partitions. Go to "Determining if the System Has
Logical Partitions" on page 943, before continuing with this procedure.
Determine the disk unit 1 type number. It is printed on a label on the front of the system
frame.
If the system does not have a label that identifies the disk unit type, you can determine the
part number of the disk unit by looking at a label located on the disk unit. You must
remove the disk unit to see this label.
Exchange the disk drive and logic card for the disk unit type you have (see "Type, Model,
and Part Number list" on page 885).
To locate the load source for a system that does not have multiple partitions see
"Determining the Load Source Disk and Alternate IPL Device" on page 944. To locate the
load source for the Primary partition on a system that has multiple partitions see
"Determining the Load Source Disk and Alternate IPL Device" on page 944. To locate the
load-source for a secondary partition see iSeries Service Functions.
FI00099
FI00099 indicates that the Licensed Internal Code failed or responded in an unpredictable
way.
Ask your next level of support for assistance.
FI00121
FI00121 indicates that any tape or optical storage device attached to the I/O (SCSI) bus of
this IOP may be the failing item.
Use the device type to determine the part.
FI00122
FI00122 indicates that a reserved IOA port on the IOP is the failing item.
If the IOP is type 2624, the failing item is type 6146 IOA.
FI00123
See the symbolic FRU "DEVTERM" on page 525.
FI00124
FI00124 indicates that the control panel is the failing item.
For part number information, see 9251 and 507x, 508x Expansion Tower(s) Control Panel in
the parts section of Migrated Expansion Tower Problem Analysis, Repair and Parts.
v For a failing logical partition, other than the Primary partition, on systems with
multiple logical partitions, go to the "Work with partition status" screen and
determine the active IPL type (source).
v For a failing Primary partition or for systems with only one partition select function
01 (Select IPL) on the control panel to display the active IPL type.
storage IOA first using the STORIOA symbolic FRU. To locate the load source for a
system that does not have multiple partitions see "Determining the Load Source Disk
and Alternate IPL Device" on page 944. To locate the load source for the Primary
partition on a system that has multiple partitions see "Determining the Load Source
Disk and Alternate IPL Device" on page 944. To locate the load-source for a secondary
partition see iSeries Service Functions.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Failing Items
481

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I sb3I 840I sb2

Table of Contents