Description/Action Perform all actions before exchanging
Code
Failing Items
6984
High Speed Link (HSL) loop status message.
An HSL I/O loop has switched to its alternate path. This is an
informational SRC only.
Word 7 of the SRC contains the loop number in the leftmost 4
digits. The loop number is in hexadecimal format. You must
convert the hexadecimal loop number into decimal format to
recognize the loop number in HSM.
This SRC can be caused by a tower on the HSL loop powering
off.
This SRC may also appear in the SAL with a B600 6982 or B600
6981 logged at approximately the same time. In that case the
other SRC is reporting a failure and this SRC is reporting that
the alternate HSL path is now being used. Service the other
SRC if present, otherwise ignore this SRC.