b. Try the new power supply in each of the other positions listed in the table.
c. If the problem still is not fixed, reinstall the original power supply and go
to the next FRU in the list.
2. Is the SRC 1xxx-13xx?
No
Yes
↓
For 1xxx-13xx SRCs use this table:
Unit Reference Code
1300
1301
1302
1303
1304
1305
Notes:
a. If the new power supply doesn't fix the problem, reinstall the original
power supply.
b. Try the new power supply in each of the other positions listed in the table.
c. If the problem still is not fixed, reinstall the original power supply and go
to the next FRU in the list.
3. Is the SRC 1xxx-15xx or 19xx?
No
Yes
↓
For 1xxx-15xx or 19xx SRCs in a system unit or secondary I/O frame
with single AC line cord, except FC 5078/0578, use this table:
Unit Reference Code
1510, 1511, 1512, 1513,
1514, 1516
1520, 1521, 1522, 1523,
1524, 1526
1530, 1531, 1532, 1533,
1534, 1536
1910, 1911, 1912, 1913
1920, 1921, 1922, 1923
Notes:
a. If the new power supply doesn't fix the problem, reinstall the
original power supply.
b. Try the new power supply in each of the other positions listed in
the table.
c. If the problem still is not fixed, reinstall the original power supply
and go to the next FRU in the list.
For 1xxx-15xx and 19 xx SRCs in a system unit or secondary I/O
frame with dual AC line cord, except FC 5078/0578, use this table:
Also perform "Power PIP11" on page 396.
Chapter 3. Problem Isolation Procedures (PIPs), Failing Items, and Symbolic FRU Isolation
Power Supply
P01
P02
P03
P04
P05
P06
Power Supply
P01
P02
P03
PP1
PP2
Symbolic FRUs
Part Number
21H7719
21H7719
21H7719
21H7719
21H7719
21H7719
Part Number
90H6629
90H6629
90H6629
24L0728
24L0728
577