Workstation Adapter Console PIPs
2. Perform the following to make dedicated service tool (DST) available:
3. Do you have SRC A600 5001, A600 5004, A600 5007, or B075 xxxx (where xxxx
4. Does SRC 6A59 5007 occur?
5. Did SRC A600 5001, A600 5004, or 6A59 5008 occur?
478
iSeries Model 830, 840, SB2, and SB3 Problem Analysis, Repair and Parts V5R1
Notes:
a. Card information:
– Hardware that is associated with 6A59 feature is the type 2745 card.
b. Cable information:
– The cable attaches directly to the IOA.
Did you find a problem with any of the conditions listed above?
No
Yes
Correct the problem. Then perform an IPL of the system.
This ends the procedure.
a. If there is an alternative console, ensure that it is powered on.
b. Ensure that Manual mode on the control panel is selected (see iSeries Service
Functions).
c. Select function 21 (Make DST Available) on the control panel and press
Enter.
Does a display appear on either the console or any alternative console?
No
Yes
Complete the IPL.
When the operating system display appears, use the Work with
Problem command (WRKPRB) or Analyze Problem command (ANZPRB) to
analyze and correct or report any console problems .
This ends the procedure.
is any value)?
No
Yes
Perform the following:
a. Disconnect any cables that are attached to the IOA.
b. Install the wrap plug on the IOA. The 2745 wrap plug label is QQ.
c. Perform an IPL in Manual mode.
No
Yes
One of the following is causing the problem:
v Workstation emulation program
v Workstation
v Workstation console cable
This ends the procedure.
No
Yes
The Type 2745 workstation adapter is the failing item.
This ends the procedure.