Description/Action If only a type number is listed, go to the "Type, Model, and Part
Failing Item Code
Number list" on page 885 to determine the part number.
FI00130
FI00130 indicates that the Licensed Internal Code for one of the IOPs or IOAs is the failing
item.
Determine the IOP or IOA type and location (see "SRC Address Formats" on page 936).
Get the type from the card at that address.
Look for PTFs associated with the reference code and the identified hardware type and
have the customer apply them.
FI00131
FI00131 indicates that one of the IOPs or IOAs, if active, is the failing item.
Determine the IOP or IOA type and location (see "SRC Address Formats" on page 936).
Get the type from the card at that address.
Use the IOP or IOA type to determine the part.
FI00132
FI00132 indicates that one of the IOAs is the failing item.
Perform "BUS-PIP5" on page 285 to isolate the failing IOA.
FI00141
FI00141 indicates that the IOP for the 7208 Tape Drive is the failing item.
The failing IOP is the type 2621 IOP.
FI00142
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI00180
This failing item is in a migrated tower. See the Migrated Expansion Tower Problem Analysis,
Repair and Parts failing item table for this failing item.
FI00182
FI00182 indicates that the SPD Optical Bus Driver is the failing item.
v If the fifth character of word 5 (xxxx xxxx) is 1, 5, 9, or D—2686 (266Mb/s)
v If the fifth character of word 5 (xxxx xxxx) is 3, 7, B, or F—2688 (1062Mb/s)
FI00185
FI00185 indicates that the 12-port ASCII workstation attachment cable is the failing item.
FI00186
FI00186 indicates that the optical cable in the top position (lower number bus) of the SPD
optical Bus Driver is the failing item.
FI00187
FI00187 indicates that the optical cable configuration is the failing item.
Perform Bus PIP 1 in Migrated Expansion Tower Problem Analysis, Repair and Parts to
determine the failing item.
FI00189
FI00189 indicates that the local SPD bus adapter configuration is the failing item.
Perform Bus PIP 1 in Migrated Expansion Tower Problem Analysis, Repair and Parts to
determine the failing item.
FI00200
FI00200 indicates that the AC module or the removable power cable is the failing item.
The following list shows the possible failing AC modules:
v System Unit — part SPNLCRD
v System Unit Expansion (FC 5070, 5072), Storage Expansion Tower (FC 5080, 5082)—part
v System Unit Expansion (FC 5071, 5073), Storage Expansion Tower (FC 5081, 5083)—part
See "Power Cord Part Numbers and Receptacle Descriptions" on page 891 to determine the
power cable part number for systems in your country.