Plus - IBM iSeries Series Hardware Problem Analysis And Isolation

Hide thumbs Also See for iSeries Series:
Table of Contents

Advertisement

b. Replace each card one at a time, powering on the system or tower (as instructed in the remove
and replace procedure) after you replace each one, until the problem appears again. The last
card that you replaced before the problem appeared again is the failing item. Continue with the
next step.
3. Use the links in the table below to locate and replace the failing item.
Table 1. Failing item for symbolic FRU PIOCARD
System model, tower, expansion
unit, or machine type
Model 270
(Embedded IOP DSA = 000110xx)
Model 270
Models 800 and 810
Models 800 and 810
Model 820
(Embedded IOP DSA = 000110xx)
Model 820
Model 825
Models 830 and SB2 base I/O tower
(FC 9074)
Models 840 and SB3 base I/O tower
(FC 9079)
Models 870 and 890
FC 5074 Expansion I/O Tower
FC 5075 Expansion I/O Tower
FC 5078, FC 0578 Expansion I/O Unit PCI IOP or IOA
FC 5079 (1.8m expansion tower)
FC 5088 or FC 0588 Expansion I/O
Unit
FC 5095, FC 0595 Expansion I/O Unit PCI IOP or IOA
External xSeries Server
This ends the procedure.

PLUS

For use by authorized service providers.
416
iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis and
Isolation
Name of FRU to exchange
System unit backplane
PCI IOP or IOA
System unit backplane
PCI IOP or IOA
System unit backplane
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
PCI IOP or IOA
Integrated xSeries Adapter Card
Link to locations information and
remove and replace procedures
See Locations - Model 270.
You will need the processor feature
code (characters 5 through 8 of function
20 on the control panel).
See Locations - Model 270.
You will need the processor feature
code (characters 5 through 8 of function
20 on the control panel).
See Locations - Models 800 and 810
You will need the processor feature
code (characters 5 through 8 of function
20 on the control panel).
See Locations - Models 800 and 810
See Locations - Model 820
See Locations - Model 820
See Locations - Model 825
See Locations - Models 830/SB2
System Unit with FC 9074 Base I/O
Tower
See Locations - Models 840/SB3
system unit with processor tower and
FC 9079 base I/O tower
See Locations - Models 870 and 890
See Locations - FC 5074 Expansion I/O
Tower
See Locations - FC 5075 Expansion I/O
Tower
See Locations - FC 5078, 0578
Expansion I/O Unit
See Locations - FC 5079 Expansion I/O
Tower
See Locations - FC 5088, FC 0588
Expansion I/O Unit
See Locations - FC 5095, FC 0595
Expansion I/O unit
See Locations - Integrated xSeries
adapter card (IXA).

Advertisement

Table of Contents
loading

Table of Contents