Parameter Reference
•
M1 = Nortel Meridian-1/Meridian SL-1
•
Norstar = Nortel Norstar Key Systems
Optiset_300ECS = Siemens Hicom 300E CS
•
Optiset_300E = Siemens Hicom 300E
•
•
Lucent = Lucent DEFINITY G3
•
Magix = Merlin Magix
•
NEC_IMG = NEC IMG
NEC_IMX = NEC IMX
•
•
NEC_NEAX = NEC NEAX or NEC 2400 IPX
•
Rolm_8000 = Rolm 8000
•
Rolm_9751_SW9005 = Rolm 9751 with software release 9005 or earlier
Rolm_9751_SW9006 = Rolm 9751 with software release 9006 or earlier
•
Default Value = None
INI File Parameter Name = telPbxType
Note: If Optiset_300E is selected as the Telephony Switch Type, the setting of subscriber Message
Waiting Indicator (MWI) lights is not supported and the Analog version of the DMG1000 (Models
DMG1008LS, DMG1004LS) should be used to set/clear subscriber MWIs on this switch type.
Note: Unit requires a restart if this parameter value is changed.
3.3.2.2
PCM Coding
Description: Sets the Media Gateway to the PCM coding mode used by the PBX.
Allowed Values:
•
µLaw = PBX uses µLaw coding.
•
aLaw = PBX uses ALaw coding.
Default Value = µLaw
INI File Parameter Name = dspPcmCoding
3.3.3
Serial Port, COM1 Group
The Serial Port, COM1 group parameters are used to configure the DMG1000 serial interface port
DIAGNOSTICS connector and the DMG2000 COM1 port connector. The system parameters in the
Serial Port group include:
•
Serial Port Baud Rate
Serial Port Parity
•
•
Serial Port Data Bits
•
Serial Port Stop Bits
52
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation