Initial Wait For Inband Cpid; Inband Cpid Complete Timeout; Analog Interface Type - Dialogic DMG1000 User Manual

Dialogic 1000 and 2000 media gateway series
Hide thumbs Also See for DMG1000:
Table of Contents

Advertisement

Parameter Reference
CPID Parsing Configuration
3.4.4.1

Initial Wait for Inband CPID

Description: Specifies the number of milliseconds the DMG1000 will wait for the first inband
DTMF digit to arrive after answering an incoming PBX call.
Allowed Values: 100 to 10000 milliseconds
Default Value = 2000 milliseconds
INI File Parameter Name = telInbCpidStartMs
3.4.4.2

Inband CPID Complete Timeout

Description: Specifies the number of milliseconds the DMG1000 will wait for each subsequent
inband DTMF digit to arrive. If no digit is received within this time, the CPID is assumed to be
complete.
Allowed Values: 100 to 2000 milliseconds
Default Value = 300 milliseconds
INI File Parameter Name = telInbCpidEndMs
3.4.4.3

Analog Interface Type

Description: Specifies the type of analog interface to which the DMG1000 is connected.
Allowed Values:
PBX
Central Office
Default Value = PBX
INI File Parameter Name = telAlgIfType
3.4.4.4
Central Office (Type I) Caller ID Type
Description: Specifies the Type I Caller ID modulation to use, either Bellcore FSK (North
America and Australia), DTMF (parts of Europe, including Sweden, Finland, Denmark,
Netherlands, and Iceland), or none. This configuration option is only enabled when the Analog
Interface Type is Central Office.
Note: If the Caller ID type is DTMF, then CPID parsing rules will need to be specified. See
"Media Gateway Parsers"
60
for further information on the creation and use of parsing rules.
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Chapter 6,
Dialogic Corporation

Hide quick links:

Advertisement

Table of Contents
loading