3.10.2.10

Call Progress Filter Debounce

Description: Specifies the debounce time in milliseconds for the Call Progress Tone Detector. This
value defines the minimum time that a call progress signal must be present before the detector is
triggered.
Allowed Values: 100 to 32768 milliseconds
Default Value = 100 milliseconds
INI File Parameter Name = cpFilterDebounce
Note: Unit requires a restart if this parameter value is changed.
3.10.2.11
Call Progress Filter Percent (DMG1000 Only)
Description: Specifies the percent ratio between tone power and total power for the Call Progress
Tone Detector. Call progress tone signals whose power is a smaller percentage of total power than
this value will be ignored.
Allowed Values: 25 to 87%
Default Value = 45%
INI File Parameter Name = cpFilterPercent
Note: Unit requires a restart if this parameter value is changed.
3.10.2.12
Call Progress Filter Low Cutoff (DMG1000 Only)
Description: Specifies the low cut-off frequency for the Call Progress Tone Detector. Call progress
signals below this frequency will be ignored.
Allowed Values: 250 Hz to 1000 Hz
Default Value = 300 Hz
INI File Parameter Name = cpFilterLowCuttoff
Note: Unit requires a restart if this parameter value is changed.
3.10.2.13
Call Progress Filter High Cutoff (DMG1000 Only)
Description: Specifies the high cut-off frequency for the Call Progress Tone Detector. Call
progress signals above this frequency will be ignored.
Allowed Values: 500 Hz to 2000 Hz
Default Value = 650 Hz
®