Dialogic DMG1000 User Manual page 73

Dialogic 1000 and 2000 media gateway series
Hide thumbs Also See for DMG1000:
Table of Contents

Advertisement

Allowed Values: *, #, None
Default Value = None
INI File Parameter Name = dpInbVoipAltRoute
Outbound Call Connect Timeout (Phone Emulating Only)
Description: Specifies the time in milliseconds that the Media Gateway will wait for a connect
event on an outbound circuit call. If no connect event is received within the time specified, the
Media Gateway will automatically transition the call to the connected state.
Allowed Values: 0 to 60000 milliseconds
Default Value = 10000 milliseconds.
INI File Parameter Name = telConnectToutMs
Wait for Ringback/Connect on Blind Transfer (Phone Emulating Only)
Description: Specifies whether the gateway will wait for the detection of ringback tone or
connection before completing a blind transfer of a circuit call. If Yes is selected, blind transfers will
wait for a ringback tone or connect event (voice) before completing the transfer. If No is selected, a
blind transfer will be completed as soon as the destination number is dialed. Valid only in
OnAnswer connect mode.
Allowed Values: Yes, No
Default Value = Yes
INI File Parameter Name = telBlindXfrWaitConfirm
Hunt Group Extension (Phone Emulating Only)
Description: If the telephony ports are configured in a Hunt Group on the switch, then enter the
Hunt Group extension number in this field. The gateway will use this field to ignore the Hunt
Group extension when generating the call party information. This ensures that the Hunt Group
extension number is not mistaken for a calling or called party number.
Allowed Values: Any valid dialable number string up to 7 characters
Default Value = (no default value)
INI File Parameter Name = telHuntGroupExtn
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation
Parameter Reference