3.4.3
Message Waiting Control Group
The Analog parameters in the Message Waiting Control group include:
•
MWI Confirmation Tone
Use Same Port for MWI Clear/Set
•
3.4.3.1
MWI Confirmation Tone
Description: Specifies whether or not the PBX sends a confirmation tone to signal the successful
completion of a Message Waiting Indication (MWI) request.
Allowed Values:
Yes = PBX will send a confirmation tone.
•
•
No = PBX will not send a confirmation tone.
Default Value = No
INI File Parameter Name = telMwiConfirm
3.4.3.2
Use Same Port for MWI Clear/Set
Description: Specifies if the PBX requires that the telephony station that set an MWI be used to
clear the MWI.
Note: Some PBX types require that the port that set an MWI be the same port that clears the MWI.
Allowed Values:
•
Yes = Use the same port to set and clear the MWI.
No = Not necessary to use the same port to clear an MWI that was used to set the MWI.
•
Default Value = Yes
INI File Parameter Name = telMwiSamePort
3.4.4
CPID Group
The Analog parameters in the Inband CPID group include:
Initial Wait for Inband CPID
•
•
Inband CPID Complete Timeout
•
Analog Interface Type
•
Central Office (Type I) Caller ID Type
•
Central Office (Type I) Caller ID Alert Type
Central Office (Type I) FSK Caller ID Expiration
•
•
Central Office (Type I) FSK Caller ID Timeout
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation
Parameter Reference
59