Unit Status
Figure 35. E-mail Parameters in Traps and Alarms Section of Gateway Advanced Web Page
E-Mail Alarms Enabled: Set to yes to generate alarm e-mails
E-Mail Minimum Alarm Severity: The gateway has three levels of alarms: Info, Warn and Error,
where Info is the lowest level alarm and Error is the highest. This field specifies the lowest level
that generates e-mails.
Destination E-Mail List: A list of e-mail addresses, separated by semi-colons, to which the alarm
e-mails are sent.
E-Mail Server IP Address: The IP address of your network's e-mail server.
Source E-Mail Address: The e-mail address placed in the from field of the alarm e-mail. Default
value is shown.
E-Mail Format
The e-mail's title specifies the alarm's severity, the gateway's IP address and a short description of
the alarm. The e-mail's body starts with five standard lines followed by optional lines.
Line 1: the alarm's severity (Info, Warn or Error)
Line 2: the IP address of the gateway
Line 3: the MAC address of the gateway
Line 4: the alarm's identification number (in hexadecimal)
Line 5: a short description of the alarm
Line 6: the physical port number associated with the alarm (is omitted for alarms not
associated with ports)
Remaining Lines: detailed text associated with the alarm (present for a limited number of
alarms that require additional information)