Default Value = None
INI File Parameter Name = cpToneEvent
3.11.3

Tone Name

Description: Specifies the text name associated with this tone definition.
Allowed Values: String with length between 0 - 31 characters
Default Value = Empty string
INI File Parameter Name = cpToneName
3.11.4

Cadence Type

Description: Specifies the cadence type for this tone definition.
Allowed Values:
Continuous = an "on" tone with no "off".
OnOff = an "on" cadence followed by an "off" cadence.
OnOffQuick = detection is reported at the end of the "off" period following the first valid "on"
period.
Alternating = two tones that alternate with no "off" time in between.
Sequential = one, two or three tones that come in sequence.
Default Value = Continuous
INI File Parameter Name = cpCadenceType
3.11.5

Number of Cadence Cycles

Description: Specifies the number of cadence cycles for this tone definition.
Allowed Values: 1-10
Default Value = 2
INI File Parameter Name = cpCadenceNumCycles
3.11.6

Tone Frequency

Description: Specifies the frequencies for this tone definition. A tone can be described by up to
three (3) frequencies. For Alternating and Sequential Tones, the top frequency is the first frequency,
®
Dialogic