Delay After Flash-Hook (Msecs); Inform On Pbx Calling Number Update (Phone Emulating Only) - Dialogic DMG1000 User Manual

Dialogic 1000 and 2000 media gateway series
Hide thumbs Also See for DMG1000:
Table of Contents

Advertisement

Parameter Reference
the VoIP endpoint. This allows the gateway to send the CPID information as part of the initial call-
request to the VoIP endpoint. If this parameter is disabled, then the gateway will not answer the
inbound TDM call until after the call-request is sent to the VoIP endpoint and the VoIP endpoint
answers the call-request. In this case, the CPID information will not be part of the initial call-
request to the VoIP endpoint.
Note: This parameter is valid only when the gateway is configured to receive Type II CPID (post-answer
CPID).
If this parameter is disabled, the gateway will not answer the inbound TDM call until after the call-
request is sent to the VoIP endpoint and the VoIP endpoint answers the call-request. In this case, the
CPID information will not be part of the initial call-request to the VoIP endpoint.
Note: This parameter can only be changed in the configuration file. It is not accessible through the Web
interface.
Allowed Values:
Yes = Gateway will auto-answer the inbound TDM call.
No = Gateway will not auto-answer the inbound TDM call.
Default Value = No
INI File Parameter Name = telAutoAnswer
3.12.2

Delay After Flash-Hook (msecs)

Description: Specifies the duration (in milliseconds) to delay after a Flash Hook if a dial tone
confirmation is not expected.
Note: This parameter can only be changed in the configuration file. It is not accessible through the Web
interface.
Allowed Values: 100 to 10000 msec
Default Value = 2000 msec
INI File Parameter Name = telFlashHookNoDialToneDelayMs
3.12.3
Inform On PBX Calling Number Update (Phone Emulating
Only)
Description: When this parameter is enabled (Yes), the Media Gateway will send an informational
VoIP message to the IP peer when the calling number on the circuit side changes during the call.
Note: This parameter can only be changed in the configuration file. It is not accessible through the Web
interface.
Allowed Values:
Yes = Media Gateway will generate this informational message.
130
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents