Parameter Reference
These call progress tones can be viewed and edited manually from the Web interface if the
characteristics are known, or the Media Gateway can be directed to analyze and learn the
characteristics of specific call progress tones. For more information on viewing, editing, learning,
and validating call progress tones from the Web interface, see
Progress
Tones".
The call progress tone parameters include the following:
ID

Tone Event

Tone Name
Cadence Type
Number of Cadence Cycles
Tone Frequency
Tone Frequency Deviation
Tone Cadence Time
Tone Cadence Time Deviation
In addition, you can edit the INI file directly if needed as discussed in the following topic:
Editing the INI File Directly
3.11.1
ID
Description: Automatically assigned IDs for reference. These IDs cannot be edited.
3.11.2
Tone Event
Description: Specifies the tone event for this tone definition.
Allowed Values:
None
Dialtone
Ringback
Busy
Congestion
Disconnect
Error
SIT
Pager
Modem
Fax
FaxCNG