Pbx Self Verification Test - Dialogic DMG1000 User Manual

Dialogic 1000 and 2000 media gateway series
Hide thumbs Also See for DMG1000:
Table of Contents

Advertisement

Device Not Available
User Busy
User Not Found
If an error occurs some other suggestions are:
Verify gateway PBX/PSTN interface is in-service and configured properly.
Verify destination PBX/PSTN endpoint is valid and in-service.
Run the test again with the Trace Capture and Network Capture diagnostic utilizes started to
log the detailed call flow of the VoIP interface diagnostic test.
9.2.2.3
Call Log
The test results from the PBX/PSTN interface diagnostic tool are also stored in the Media Gateway
call log. The Source field will contain From Test App to indicate that the connection was created
by a diagnostic application.
The call log is accessible through the Web by selecting the Call Log link on the left side menu of
any Web page.
Figure 46. PBX/PSTN Interface Call Log Web Page
9.3

PBX Self Verification Test

PBX Self Verification is discussed in the following topics:
PBX Self Verification Test Overview
PBX Self Verification Test Operation
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation
PBX/PSTN interface is not in-service
Destination number is busy (in-use)
Destination number not found at PBX/PSTN endpoint
Diagnostics
203