Figure 53. PBX Self Verification Test Results
9.3.2.5
Test Failures
If a failure occurs some suggestions are:
•
Verify PBX interface is in-service and configured properly
•
Verify gateway is configured for specific PBX interface (is there a default .ini file)
•
Run the test again with a minimum number of extensions configured and in Sequential test
mode.
•
Run the test again with the Trace Capture diagnostic utility started to log the detailed call
flow of the PBX self verification diagnostic test.
•
Use the PBX/PSTN Interface diagnostic utility to test Initiate Call and Send Message Waiting
Status on a particular interface and channel.
Check the Call Log for the call end reason of the connections used in the diagnostic tests.
•
Some of the most common test result failures and causes are:
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation
Diagnostics
211