Figure 53. PBX Self Verification Test Results
9.3.2.5
Test Failures
If a failure occurs some suggestions are:
Verify PBX interface is in-service and configured properly
Verify gateway is configured for specific PBX interface (is there a default .ini file)
Run the test again with a minimum number of extensions configured and in Sequential test
mode.
Run the test again with the Trace Capture diagnostic utility started to log the detailed call
flow of the PBX self verification diagnostic test.
Use the PBX/PSTN Interface diagnostic utility to test Initiate Call and Send Message Waiting
Status on a particular interface and channel.
Check the Call Log for the call end reason of the connections used in the diagnostic tests.
Some of the most common test result failures and causes are:
®
Dialogic
1000 and 2000 Media Gateway Series User's Guide — September 2007
Dialogic Corporation
Diagnostics
211