B.1 Overview; B.2 Modes; B.2.1 Om-73 Mode - Comtech EF Data SLM-5650A Installation And Operation Manual

Satellite modem
Hide thumbs Also See for SLM-5650A:
Table of Contents

Advertisement

B.1
Overview
This appendix provides the end user with reference guides for the following operational
parameters:
Section B.2 Modes provides tables showing the various operating modes' available data
rates and ranges.
Section B.3 Clocking Options provides information about common clocking options and
recommended configurations.
Section B.4 Buffering.
B.2
Modes
The Data Rates and Symbol Rates shown in the following tables all assume that Transmission
Security (TRANSEC) is turned off. In order to calculate the max data rate with TRANSEC on,
the max data rate shown in the table becomes a max aggregate data rate. The real data rate can be
calculated by dividing the TRANSEC overhead rate from the aggregate data rate. The TRANSEC
overhead rate can be calculated for any TRANSEC Frame Length (N) as follows:
TRANSEC Overhead Rate = (3 + 16 * N) / (16 * N)
B.2.1
OM-73 Mode
Modulation Type
BPSK 1/1
BPSK 1/2
BPSK 3/4
BPSK 7/8
QPSK 1/1
QPSK 1/2
QPSK 3/4
QPSK 7/8
OQPSK 1/1
OQPSK 1/2
Appendix B. OPERATIONS
Data Rate (kbps)
Min
64
64
64
64
64
64
64
64
64
64
REFERENCE
Max
Min
8472
64
15000
128
22500
85.333
26250
73.142
20000
32
30000
64
45000
42.666
51840
36.571
20000
32
30000
64
B–1
Symbol Rate (ksps)
Max
10000
30000
29999.999
30000
10000
30000
30000
29622.857
10000
30000

Advertisement

Table of Contents
loading