Comtech EF Data SLM-5650C CyberLynx Installation And Operation Manual

Comtech EF Data SLM-5650C CyberLynx Installation And Operation Manual

Table of Contents

Advertisement

Quick Links

SLM-5650C CyberLynx
TM
SLM-5650C CyberLynx
ODU
TM
Satellite Modem
Installation and Operation Manual
Part Number MN-SLM-5650C
Revision 1
IMPORTANT NOTE: The information contained in this document supersedes all previously published
information regarding this product. Product specifications are subject to change without prior notice.

Advertisement

Table of Contents
loading

Summary of Contents for Comtech EF Data SLM-5650C CyberLynx

  • Page 1 SLM-5650C CyberLynx SLM-5650C CyberLynx Satellite Modem Installation and Operation Manual Part Number MN-SLM-5650C Revision 1 IMPORTANT NOTE: The information contained in this document supersedes all previously published information regarding this product. Product specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    SLM-5650C Satellite Modem Revision 1 Copyright © 2019 Comtech EF Data. All rights reserved. Printed in the USA. Comtech EF Data, 2114 West 7 Street, Tempe, Arizona 85281 USA, 480.333.2200, FAX: 480.333.2161 Revision History Date Description Mar 2019 Initial Release.
  • Page 3: Table Of Contents

    Galvanic Isolator Use ..........................iii Restricted Access Location ........................iv Battery Warning ............................iv Operating Environment ..........................iv Product Support ............................iv Comtech EF Data Headquarters ....................... iv Warranty Policy ............................v Limitations of Warranty..........................v Exclusive Remedies ..........................vi CHAPTER 1.
  • Page 4 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 CHAPTER 3. EXTERNAL CONNECTORS AND PINOUTS .............. 3–1 Overview ............................3–1 3.1.1 SLM-5650C Connector Overview ..................... 3–1 3.1.2 SLM-5650C-ODU Connector Overview ..................3–3 IF Connectors ..........................3–4 3.2.1 SLM-5650C Tx, Rx L-Band IF Interface Connectors ..............3–4 3.2.2 SLM-5650-ODU Tx, Rx L-Band IF Interface Connectors ............
  • Page 5 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Admin | Time ....................... 6–10 Admin | FAST ......................6–11 Admin | Upgrade ......................6–12 6.4.3 Configuration (Modem Configuration) Pages ................. 6–13 Configuration | Modem ....................6–13 Configuration | Utils ..................... 6–16 Configuration | LoadStore ................... 6–21 Configuration | Spreading ...................
  • Page 6 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.1 Initial System Check ......................... A–2 A.3.1.1 SLM-5650C Status Indicators ..................A–2 A.3.1.2 SLM-5650C-ODU Status Indicators ................A–3 A.3.2 System Check Using IF Loopback and Internal BERT ............. A–5 A.3.2.1 Tx Waveform Check ...................... A–6 A.3.2.2 Rx Waveform Check .....................
  • Page 7 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 LIST OF TABLES Table 1-1. SLM-5650C / SLM-5650C-ODU Physical Characteristics ............1–2 Table 1-2. Summary of General Specifications ..................1–9 Table 1-3. Summary of Modulator Specifications..................1–9 Table 1-4. Summary of Demodulator Specifications ................1–10 Table 1-5.
  • Page 8 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 LIST OF FIGURES Figure 1-1. SLM-5650C Satellite Modem (Indoor Unit) ................1–1 Figure 1-2. SLM-5650C-ODU Satellite Modem (Outdoor Unit) ..............1–1 Figure 1-3. SLM-5650C / SLM-5650C-ODU Block Diagram ..............1–3 Figure 1-4. SLM-5650C Indoor Unit Dimensional Envelope ..............1–5 Figure 1-5.
  • Page 9 Automatic Gain Control Assignment Operator AUPC Automatic Uplink Power Control 6-14 Bit Error Rate Built In Test Block Up Converter CEFD Comtech EF Data Command Line Interface Preface ii Cyclic Redundancy Check 6-32 Code Word 6-14 Direct Current Department of Defense...
  • Page 10 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Acronym Description First Use Page Number Low Latency Low Noise Block Down Converter LVDS Low Voltage Differential Signaling 6-14 M&C Monitor and Control Media Access Control 6-32 Management Information Base Normally Closed Normally Open Network Management System Object Identifier Personal Computer...
  • Page 11 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Units of Measurement Unit / Symbol Definition Ω Ampere bits per second ˚C Celsius (degrees) Hertz kilo Hertz decibel Decibels relative to the carrier Decibel-milliwatts ˚F Fahrenheit (degrees) Kbps Kilobit per second kilogram ksps Kilo symbols per second lbs.
  • Page 12 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Table of Contents TOC-10...
  • Page 13: Preface

    Conventions and References Patents and Trademarks See all of Comtech EF Data's Patents and Patents Pending at http://patents.comtechefdata.com. Comtech EF Data acknowledges that all trademarks are the property of the trademark owners. Related Documents The following documents are referenced in this manual: •...
  • Page 14: Warnings, Cautions, Notes, And References

    A NOTE: gives you important information about a task or the equipment. A REFERENCE directs you to important operational information or details furnished elsewhere, either in the manual or in adjunct Comtech EF Data publications. Examples of Multi-Hazard Notices...
  • Page 15: Recommended Standard Designations

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Recommended Standard Designations The Electronic Industries Association (EIA) designations supersede the Recommended Standard (RS) designations. References to the old designations may be shown when depicting actual text (e.g., RS-232) displayed on front panel menus, Web Server pages, serial remote interfaces, Telnet Command Line Interfaces (CLIs), or unit rear panels.
  • Page 16: Restricted Access Location

    CORROSIVE OR EXPLOSIVE ATMOSPHERES Product Support For all product support, please call: +1.240.243.1880 +1.866.472.3963 (toll free USA) By email: esc@comtechefdata.com Comtech EF Data Headquarters http://www.comtechefdata.com Comtech EF Data Corp. 2114 West 7th Street Tempe, Arizona USA 85281 +1.480.333.2200 Preface MN-SLM-5650C...
  • Page 17: Warranty Policy

    Comtech EF Data Corporation, would affect the reliability or detracts from the performance of any part of the product, or is damaged as the result of use in a way or with equipment that had not been previously approved by Comtech EF Data Corporation.
  • Page 18: Exclusive Remedies

    The buyer shall pass on to any purchaser, lessee, or other user of Comtech EF Data Corporation’s products, the aforementioned warranty, and shall indemnify and hold harmless Comtech EF Data...
  • Page 19: Chapter 1. Introduction

    Outdoor Unit with Caps without Caps Figure 1-2. SLM-5650C-ODU Satellite Modem (Outdoor Unit) The SLM-5650C CyberLynx Satellite Modem is offered in two unique packages: • The SLM-5650C indoor unit (referred to as the SLM-5650C), shown in Figure 1-1, uses conductive cooling and provides for mounting in any orientation via either the thermal mounting rails or directly to the top or bottom surface.
  • Page 20: Table 1-1. Slm-5650C / Slm-5650C-Odu Physical Characteristics

    • Supports Direct Sequence Spread Spectrum (DSSS) waveform and Comtech EF Data (CEFD) proprietary Low Density Parity Check (LDPC) Forward Error Correction (FEC) in three block sizes (Ultra Low Latency (ULL), Low Latency (LL), High Performance (HP)) and Turbo Product Code (TPC) FEC (3/4, 5/16, 21/44, 17/18, and 7/8 code rates).
  • Page 21: Functional Description

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Functional Description 14 bit DAC TX Level 1.8V SPI 1.8V SPI 2 Ch DAC L-Band (DAC3482, TX RF Front TX RF Output IP TX (RGMII) TX I & Q Samples (LVDS) 900mW) (SMA) M&C Config Turbo TX 3.3 / 1.8V Level...
  • Page 22: Slm-5650C / Slm-5650C-Odu Features

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 SLM-5650C / SLM-5650C-ODU Features Both modems incorporate the following features: • SWaP optimized form factor • Low weight and low power dissipation • L-Band (950 to 2000 MHz) Intermediate Frequency (IF) interface • Ethernet Interface for remote control using Telnet, SNMP, HTTP, and HTTPS •...
  • Page 23: Physical Description

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 1.3.1 Physical Description 1.3.1.1 Dimensional Envelopes Figure 1-4. SLM-5650C Indoor Unit Dimensional Envelope Introduction 1–5 MN-SLM-5650C...
  • Page 24: Figure 1-5. Slm-5650C-Odu Dimensional Envelope

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Figure 1-5. SLM-5650C-ODU Dimensional Envelope Introduction 1–6 MN-SLM-5650C...
  • Page 25: Operational Features

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 1.3.2 Operational Features 1.3.2.1 Operating Modes Both modems support Uncoded, Viterbi, Viterbi+Reed Solomon, Sequential, TPC, and LDPC modes of operation. (STANAG 4486 (EBEM) in fall 2019) 1.3.2.2 Secure Management Interfaces Chapter 6. MODEM CONFIGURATION The modems support secure management interfaces, as part of its Management Security option.
  • Page 26: Verification

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 1.3.2.5 Verification Both modems include test modes and loopbacks for rapid verification of the correct functioning of the modems. Of particular note is the IF loopback, which permits the user to perform a quick diagnostic test without having to disturb external cabling.
  • Page 27: Summary Of Specifications

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Summary of Specifications Table 1-2. Summary of General Specifications General Specifications Parameter Specifications Operating Frequency Range 950 to 2000 MHz ( in 1000 Hz steps) Modulation Types BPSK, QPSK, OQPSK, 8PSK, 8QAM, and 16QAM Digital Data Rates 8 kbps with LDPC Spreading ON 32 kbps with LDPC Spreading OFF...
  • Page 28: Table 1-4. Summary Of Demodulator Specifications

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Table 1-4. Summary of Demodulator Specifications Demodulator Specifications Parameter Specifications +10 to -55 dBm (SR>3.2 Msps) Desired Carrier +10 to 10·log (SR/32000) -75 dBM Input (SR≤3.2 Msps) where SR is in symbols per second Power Maximum Composite +20 dBm or +40 dBc...
  • Page 29: Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Performance 1.5.1 Acquisition and Timing Performance Requirements The following reference Energy per Bit to the Spectral Noise Density (Eb/No) is defined as the required Eb/No corresponding to a BER of 1 x 10 with Reed-Solomon FEC not enabled.
  • Page 30: Data Quality Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Table 1-7. Doppler Requirements Parameter C-Band X-Band Ku-Band Ka-Band Doppler Shift in Hz ± 2475 ± 3535 ± 6045 ± 11,810 Doppler Rate of Change in Hz/sec ± 226 ± 270 ± 490 ±...
  • Page 31 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Turbo Coding Mode Performance Both modems operating in the Turbo Code Mode provides back-to-back BER vs. Eb/No performance better than or equal to the values shown in Table 1-13 when using the modulation formats indicated.
  • Page 32: Ber Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BER Performance BPSK/QPSK/Offset QPSK, Viterbi Decoding Table 1-8. Viterbi Decoder BER Eb/No (dB) Specifications Viterbi Decoder Uncoded 10.8 11.6 12.4 13.0 BPSK/QPSK/Offset QPSK, Viterbi Decoding and Reed-Solomon Table 1-9. BSPK/QPSK/OQPSK Viterbi with Reed-Solomon Decoder BER Performance Eb/No (dB) Specifications Viterbi Decoder with Reed-Solomon 8PSK, Trellis Decoder...
  • Page 33: Table 1-11. 8Psk, Trellis Decoder With Reed-Solomon Ber Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 8PSK, Trellis Decoder and Reed-Solomon Table 1-11. 8PSK, Trellis Decoder with Reed-Solomon BER Performance Eb/No (dB) Specifications Trellis Decoder with Reed-Solomon 16QAM, Viterbi Decoder and Reed-Solomon Table 1-12. 16QAM, Viterbi Decoder with Reed-Solomon BER Performance Eb/No (dB) Specifications Viterbi Decoder with Reed-Solomon 10.1...
  • Page 34: Table 1-14. Sequential Decoding With / Without Reed-Solomon Ber Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Sequential Decoding with / without Reed-Solomon Table 1-14. Sequential Decoding with / without Reed-Solomon BER Performance Eb/No (dB) Specifications Sequential Decoder with / without Reed-Solomon BPSK QPSK/OQPSK DESCRIPTION Sequential – 64 kbps Sequential – 1544 kbps Sequential+RS (225,205) LDPC ULL Decoding Table 1-15.
  • Page 35: Table 1-16. Ldpc Ll Decoder Ber Performance

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 LDPC LL Decoding Table 1-16. LDPC LL Decoder BER Performance Eb/No (dB) Specification BPSK QPSK 8QAM 16QAM .378 .451 .541 LDPC HP Decoding Table 1-17. LDPC HP Decoder BER Performance Eb/No (dB) Specification BPSK (O)QPSK 8QAM...
  • Page 36 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Introduction 1–18 MN-SLM-5650C...
  • Page 37: Chapter 2. Indoor Unit Installation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 2. INDOOR UNIT INSTALLATION Installation This chapter applies to only the SLM-5650C. PROPER HEAT SINKING IS REQUIRED. For the indoor unit, make sure there is adequate heat sinking to the modem enclosure. Temperature at the modem enclosure should never exceed 50°C (122°F).
  • Page 38: Connect Power Supply

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Connect Power Supply Chapter 3. EXTERNAL CONNECTORS PINOUTS Connect the direct current (DC) power cable to the proper location on the modem by inserting the jack and threading the sleeve into the housing. A non-threaded connector may also be used. Configuration If there is any problem with installation or initial operation, read Appendix A.
  • Page 39: Determine The Modem Ip Address

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Determine the Modem IP Address Step Task Connect the serial port of the modem to the serial port of a computer. The minimum pins needed are 1, 2, & 3. Open up a terminal session using an application like Putty or Tera Term. Modify the following parameters: Emulation: VT100 Tx: CR+LF...
  • Page 40 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Installation 2–4 MN-SLM-5650C...
  • Page 41: Chapter 3. External Connectors And Pinouts

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 3. EXTERNAL CONNECTORS PINOUTS Overview 3.1.1 SLM-5650C Connector Overview The SLM-5650C connectors (Figure 3-1) provide all necessary external connections between the modem and other equipment. Table 3-1 summarizes the connectors, grouped according to service function.
  • Page 42: Table 3-1. Slm-5650C Connectors

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Table 3-1. SLM-5650C Connectors Connector Group Name Connector Type Function Type ’SMA’ female IF Output (L-Band) (Sect. 3.2) Type ’SMA’ female IF Input (L-Band) Terrestrial Data MANAGEMENT RJ-45 female 10/100Base-T, Remote Control (Sect. 3.3) TRAFFIC RJ-45 female 10/100/1000Base-T...
  • Page 43: 3.1.2 Slm-5650C-Odu Connector Overview

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 3.1.2 SLM-5650C-ODU Connector Overview The SLM-5650C-ODU connectors (Figure 3-2) provide all necessary external connections between the modem and other equipment. Table 3-1 summarizes the connectors, grouped according to service function. The outdoor unit is equiped with an On/Off switch with built-in Status LED.
  • Page 44: If Connectors

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 IF Connectors 3.2.1 SLM-5650C Tx, Rx L-Band IF Interface Connectors The L-Band IF Interfaces use standard 50 Ω Type ‘SMA’ female connectors: Table 3-3. Indoor Unit L-Band IF Interface Connectors L-Band IF Connector Description Direction 950-2000 MHz Transmit...
  • Page 45: Terrestrial Data Connectors

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Terrestrial Data Connectors 3.3.1 SLM-5650C Ethernet Traffic Connector (RJ-45) The Traffic Ethernet connection is an 8-pin type ‘RJ-45’ 10/100/1000Base-T connector and functions as an Ethernet bridge for data traffic. Auto Negotiate only. 3.3.2 SLM-5650C Ethernet Management Connector (RJ-45) The Management Ethernet connection is an 8-pin type 'RJ-45' 10/100/1000Base- T connector.
  • Page 46: Utility Connectors

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Utility Connectors Note that the pinout for the DB9 utility connector is NOT the same for the SLM-5650C and the SLM-5650C-ODU units. 3.4.1 SLM-5650C Remote Connector (DB9) This is a female Type ‘D’ 9-pin subminiature (DB9) connector that serves multi- purpose roles.
  • Page 47: Slm-5650C-Odu Remote Connector (Db9)

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 3.4.2 SLM-5650C-ODU Remote Connector (DB9) This is a male Type ‘D’ 9-pin subminiature (DB9) connector that serves multi- purpose roles. It provides RS-232 communications for a remote terminal, it provides a means to monitor the real time I and Q samples from the demodulator (constellation monitor), and it provides a receive signal strength indicator that can be used to aid in peaking an antenna.
  • Page 48: Power/Ground Connector

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Power/Ground Connector 3.5.1 SLM-5650C DC Power Connector A standard coaxial connector supplies DC power to the modem. The enclosure is threaded to accept a threaded connector sleeve for retention purposes. An non- threaded installation may also be used. See Table 3-7 for specifications. Table 3-7.
  • Page 49: Chapter 4. Update Firmware

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 4. UPDATE FIRMWARE Updating Firmware This chapter applies to both the SLM-5650C and the SLM-5650C-ODU. To ensure optimal performance, it is important to operate the modem with its latest available firmware. The modem must be in the Low Security mode (SNMP Type = SNMPV1V2c) in order to update firmware.
  • Page 50: Obtain Modem Ip Address

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Obtain Modem IP Address Chapter 7. REMOTE CONTROL If the modem IP Address is known, continue to Section 4.3. Otherwise, do the following: 1. Connect the user PC to the modems serial remote port using the appropriate adapter. 2.
  • Page 51: Chapter 5. Ethernet-Based Management

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 5. ETHERNET-BASED MANAGEMENT Introduction This chapter applies to both the SLM-5650C and the SLM-5650C-ODU. The modem features an RJ-45 10/100/1000Base-T Ethernet management interface for the purpose of remote monitor and control (M&C) of the modem. This port operates in the Auto- Negotiation and Auto-Crossover mode.
  • Page 52: Secure Ethernet Management Interfaces

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 5.2.1 Secure Ethernet Management Interfaces The varying degrees of Ethernet Management are dependent on the modem configuration. • When Management Security is disabled (i.e., SNMPv1/v2c is selected). HTTP may be used. Telnet protocol may be used. FTP protocol may be used for firmware upgrade or Secure Socket Layer (SSL) certificate upload.
  • Page 53: Http/Https (Web Server) Interfaces

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 HTTP/HTTPS (Web Server) Interfaces Chapter 6. MODEM CONFIGURATION Chapter 4. UPDATE FIRMWARE The modems embedded Web Server application provides the user with an easy to use interface to configure and monitor all aspects of the modem. The modems HTTP/HTTPS Interface requires Microsoft’s Internet Explorer 7.0 (or higher) and Mozilla Firefox 2.0 (or higher), via HTTP or HTTPS (depending on the modem’s security level setting).
  • Page 54: Snmp Interface

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 SNMP Interface The SNMP is an Internet-standard protocol for managing devices on IP networks. An SNMP- managed network consists of three key components: • The managed device. This includes the modem. • The SNMP Agent. The software that runs on the modem. The modems SNMP Agent supports SNMPv1, SNMPv2c, and SNMPv3.
  • Page 55: Snmp Community Strings

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 5.4.2 SNMP Community Strings In SNMP v1/v2c, the SNMP Community String is sent unencrypted in the SNMP packets. Caution must be taken by the network administrator to ensure that SNMP packets travel only over a secure and private network if security is a concern.
  • Page 56: Table 5-1. Alarms And Faults Snmpv1 Traps

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 The modem supports the following Alarms and Faults SNMPv1 traps / SNMPv2 notifications: Table 5-1. Alarms and Faults SNMPv1 Traps slm5650UnitAlarmV1 62471211 slm5650TxTrafficAlarmV1 62471212 slm5650RxTrafficAlarmV1 62471213 Table 5-2. Alarms and Faults SNMPv2c/SNMPv3 Notification slm5650UnitAlarmV2 1.3.6.1.4.1.6247.121.2.1.1 slm5650TxTrafficAlarmV2...
  • Page 57: Telnet Interface

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Telnet Interface Chapter 7. REMOTE CONTROL A Telnet interface is provided for the purpose of Equipment M&C via the standard Remote Control protocol. The Telnet interface requires login at the Administrator and Read/Write User Access Levels.
  • Page 58: Figure 5-2. Telnet Remote Control Interface

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Once logged into the Telnet interface, the standard remote control interface (as defined in Chapter 7. REMOTE CONTROL) is accessible as shown in this next example: Figure 5-2. Telnet Remote Control Interface Ethernet-Based Management 5–8 MN-SLM-5650C...
  • Page 59: Chapter 6. Modem Configuration

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 6. MODEM CONFIGURATION HTTP/HTTPS Interface This chapter applies to both the SLM-5650C and the SLM-5650C-ODU. It describes the functionality of the modem’s HTTP/HTTPS Interface. The operational parameters are available from these web pages. Modem Web Page Access Chapter 7.
  • Page 60: Figure 6-2. Windows Security Screen

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 For all interfaces, the Windows Security screen appears and the user is prompted to type in a valid User name and Password, whether via an integrated Web page or a dialog box like the one shown to the right.
  • Page 61: Web Interface - Operational Features

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 6.2.2 Web Interface – Operational Features Navigation This manual uses a naming format for all web pages to indicate the depth of navigation needed to view the referenced page: “Top Level Tab | 2 Level Tab.”...
  • Page 62: Text Or Data Entry

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Text or Data Entry Text boxes are provided any time an alphanumeric entry is required for access or configuration. Move the cursor to the text box, and then left-click anywhere inside the box. Then, use the keyboard to type in the desired alphanumeric string.
  • Page 63: Https Certificate

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 HTTPS Certificate The modem Firmware has a default HTTPS Certificate installed. The default certificate is a self- signed certificate built with the modem's default IP Address of 192.168.1.1 with a one-year expiration date. Since most modern web browsers will flag certificate errors and may not even allow secure connections when errors exist, most users will want to load their own certificate.
  • Page 64: Modem Web Interface

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Modem Web Interface Page Descriptions 6.4.1 Home Page Select the Home tab to continue. Home | Home From any location within the Modem Web Interface, click the Home top navigation tab to return back to this top-level page.
  • Page 65: Home | Contact

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Home | Contact The Contact page provides information on how to contact CEFD for sales or service support. Figure 6-6. Home | Contact Page Modem Configuration 6–7 MN-SLM-5650C...
  • Page 66: Admin

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 6.4.2 Admin Pages The Administrator may use these pages to: Set up user names, passwords, and the host IP Addresses, as required, to communicate with the Modem Web Interface. The Admin pages are available only to users who have logged in using the Administrator Name and Password.
  • Page 67: Admin | Snmp

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Admin | SNMP Chapter 5. ETHERNET-BASED MANAGEMENT Use this page to set and return administration information for the SNMP feature. Figure 6-8. Admin | SNMP Page Click [Submit] to save any changes made on this page. Click [Reboot Now] to reboot the modem to apply any SNMP Version change.
  • Page 68: Admin | Time

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Admin | Time Use this page to set the SNTP Server Address, local time, and modem time and date. Figure 6-9. Admin | Time Page Click [Submit] to save any changes made on this page. Modem Configuration 6–10 MN-SLM-5650C...
  • Page 69: Admin | Fast

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Admin | FAST Use this page to upgrade FAST options and turn ON/OFF the Demo Mode. Figure 6-10. Admin | FAST Page Description Parameters FAST Upgrade When you obtain a FAST access code from CEFD, it will be for a specific option register.
  • Page 70: Admin | Upgrade

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Admin | Upgrade Use this page to REFLASH the modem and change the active firmware image. “FW-xxxxxxx*.ZIP”. “FW-xxxxxxx*.ZIP” Figure 6-11. Admin | Upgrade Page There are two firmware slots in the modem. One is operational and the other is for the older firmware.
  • Page 71: Configuration (Modem Configuration)

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 6.4.3 Configuration (Modem Configuration) Pages The ‘Configuration’ pages are used to configure the Modulator, Demodulator, and Ethernet Bridge interface. Select the Modem, Utils, LoadStore, Spreading, AUPC, ODU, or TRANSEC tabs to continue. Configuration | Modem Use this page to configure modem configuration parameters including Modem Frequency Band;...
  • Page 72: Cw Code Word

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Modem Type Modem Type is a major change for the modem and will set the configuration to defaults for the selected modem type. The Tx power will be turned off. The modem types are: OM-73 •...
  • Page 73 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Frequency: The L-Band frequency range is from 950 to 2000 MHz. Spectrum: Select Normal or Invert. Spectral inversion is used for modem compatibility between modem manufactures. Scrambler: Scramblers can be set to Off, V.35, Modified-V.35, Synch (Reed Solomon), Intelsat Business Service (IBS), Turbo, or OM73.
  • Page 74: Configuration | Utils

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | Utils Use this page to configure modem operating parameters, including Real Time Clock; Test Modes; Tx Miscellaneous, Rx Miscellaneous, Circuit ID, Built-in BERT, 20 MHz Reference Adjust, and AGC Monitor. Figure 6-13. Configuration | Utils Page Click [Submit] as needed in each section to save any changes.
  • Page 75 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Real Time Clock Set to get accurate stored event times. Test Modes CW Mode: Tx-CW, Carrier Wave at the center frequency. Tx Alt-1,0: Use to confirm carrier null and offset suppression during test. IF loopback: Internal IF loop.
  • Page 76 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Stats Sample Interval: Modem Statistics will only report when the Stats Sample Interval is set to a periodic value. GBEI WAN Buffer Length: The GBEI WAN Buffer Length is the setting for the Tx Buffer for Ethernet data. It does not directly add to the processing delay for the Tx Ethernet data.
  • Page 77 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters BPSK Bit Order: Match the BPSK Bit Order for the Tx and Rx. This is used for modem to modem compatibility. Rx Misc RxData Mask / Demod Faults Mask / Eb/No Alarms Mask: Events for RxData, Demod Faults, and Eb/No Alarms can either be active or masked.
  • Page 78 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Threshold: The threshold setting was developed to match the setting on the Fireberd Test set. Match the threshold setting to the Fireberd when testing with that test set. Setting the threshold to high will allow the BERT to stay in sync at lower Eb/No values.
  • Page 79: Configuration | Loadstore

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | LoadStore Use this page to load or store modem configurations. Figure 6-14. Configuration | LoadStore Page Click [Submit] to save any changes made on this page. Description Parameters Load/Store Modem There are 10 slots for saved configurations. They are used when there is a need to Configuration recall many modem configurations.
  • Page 80: Configuration | Spreading

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | Spreading Use this page to allow configuration of the DSSS applications. Figure 6-15. Configuration | Spreading Page Description Parameters Spreading Calculator The calculator is used to determine the Chip Rate and Occupied bandwidth when DSSS spreading is used.
  • Page 81: Configuration | Aupc

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | AUPC Use this page to set the AUPC parameters. Figure 6-16. Configuration | AUPC Page Description Parameters AUPC Params This can be used by selecting overhead type as AUPC when the Modem type is set at either AUPC or LDPC.
  • Page 82: Configuration | Odu

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | ODU Use this page to view the ODU Control and to view the LNB Staus. Figure 6-17. Configuration | ODU Page Description Parameters ODU Control The LNB voltage is selectable at +13 VDC or +18 VDC. * LNB DC Power: Only turn on when connected to an LNB, otherwise leave it off to avoid damage to other modems or test equipment.
  • Page 83: Configuration | Transec

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Configuration | TRANSEC Figure 6-18. Configuration | TRANSEC Page Description Parameters Active Key Do the following steps to set the Active Key: Enter Active seed key and passphrase. The Seed Key is 32 characters, upper and lower case, and some special characters. •...
  • Page 84 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Future Key Activate Future Key: Activate the Future Key, or • Load and activate a new key • The Future Key can be activated after using all the 26 TEK numbers. Then, another set of TEK loads are available.
  • Page 85: Status

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 6.4.4 Status Pages The Status pages provide read-only status windows: General operating and configuration information about the modem; Info about installed options; Event Log; Modem Statistics; Ethernet Port Statistics; Network Processor Statistucs, Configuration Log; and Firmware Information. Select the Status, Info, EventLog, ModemStatistics, PortStatistics, ConfigLog, or Firmware tabs to continue.
  • Page 86: Status | Info

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Info Use this read-only page to view general information about the modem and installed options. Figure 6-20. Status | Info Page Modem Configuration 6–28 MN-SLM-5650C...
  • Page 87: Status | Event Log

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Event Log Use this read-only page to view a scrollable display of recorded modem events. Figure 6-21. Status | Event Log Page Click [Refresh] to update the display with the most recently logged events. Click [Clear Log] to clear the log.
  • Page 88: Status | Modem Statistics

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Modem Statistics Use this read-only page view a scrollable display of recorded modem statistics. Figure 6-22. Status | Modem Statistics Page Description Parameters Statistics Log (Statistic #) Date / Time: The first three columns display the statistic by the order in which it was logged, along with the date and time the event was recorded.
  • Page 89: Status | Port Statistics

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Port Statistics Use this read-only page to view Ethernet Port Statistics. Available Ports are LAN, WAN, and Field Programmable Gate Array (FPGA). Figure 6-23. Status | Port Statistics Page Description Parameters Port The Port Statistics page consists of a table of 64-bit counters.
  • Page 90: Table 6-1. Summary Of Counters For Port Statistics Pages

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Table 6-1. Summary of Counters for Port Statistics Pages Port Attribute Description Rx Packets Total Number of received packets. Total Number of received packets with Frame Check Rx FCS Errors Sequence (FCS) Errors. Rx Frame Errors Total number of received packets with Frame Errors.
  • Page 91: Status | Config Log

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Config Log Use this read-only page to view a scrollable display the configuration change log. Figure 6-24. Status | Config Log Page Description Parameters Configuration Select a logging level from the drop-down menu, and then click [Refresh] to begin logging or to update the page.
  • Page 92 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Description Parameters Change the Loopback to OFF and then back ON. These are the commands initiated for that change: Modem Configuration 6–34 MN-SLM-5650C...
  • Page 93: Status | Firmware

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Firmware Use this read-only page to view information about the boot firmware and bulk firmwares programmed into the modem. Modem Configuration 6–35 MN-SLM-5650C...
  • Page 94: Status | Constellation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Status | Constellation Use this read-only page to view information about the boot firmware and bulk firmwares programmed into the modem. Figure 6-25. Status | Constellation Page Modem Configuration 6–36 MN-SLM-5650C...
  • Page 95: Chapter 7. Remote Control

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 7. REMOTE CONTROL Overview This chapter applies to both the SLM-5650C and the SLM-5650C-ODU. This chapter describes the protocol and message command set for remote monitor and control of the modem. The electrical interface is an EIA-232 connection (for the control of a single device), and data is transmitted in asynchronous serial form using ASCII characters.
  • Page 96 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 All data is transmitted in framed packets. The Controller is assumed to be a PC or ASCII dumb terminal, which is in charge of the process of monitor and control. The Controller is the only device which is permitted to initiate, at will, the transmission of data. Targets are only permitted to transmit when they have been specifically instructed to do so by the Controller.
  • Page 97: Packet Structure

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Packet Structure Controller-to-Target Start of Packet Target Address Address Delimiter Instruction Code Code Qualifier Optional Arguments End of Packet < = or ? Carriage Return ASCII code 60 ASCII code 47 ASCII codes 61 or 63 ASCII code 13 (1 character) (4 characters)
  • Page 98: Target Address

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.4.2 Target Address This value is fixed to 0. The Controller sends a packet with the address of a Target – the destination of the packet. When the Target responds, the address used is the same address, to indicate to the Controller the source of the packet. The Controller does not have its own address.
  • Page 99: Instruction Code Qualifier

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.4.5 Instruction Code Qualifier 1. From Controller-to-Target, the only permitted values are: Symbol Definition The ‘=’ code is used as the Assignment Operator (AO) and is used to indicate that the parameter defined by the preceding byte should (ASCII code 61) be set to the value of the argument (s) which follow it.
  • Page 100: Optional Message Arguments

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Symbol Definition EXAMPLE: 0001/RET~ (indicating that it had finished waiting for a response and was now ready for further comms). If the Controller sends a correctly formatted command BUT the modem is in Ethernet Remote mode, it will not allow reconfiguration, (ASCI code 94) and will respond with TFQ^.
  • Page 101: Remote Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Remote Commands / Queries 7.5.1 Table Indexes Index Notes: Where Column ‘C’ = Command and Column ‘Q’ = Query, columns marked ‘X’ designate instruction code as Command only, Query only, or Command/Query. Under CODE, XXX indicates a priority command; XXX indicates a command/query valid only when the modem type has been set to AUPC;...
  • Page 102 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Sect. 7.5.5 Modem, Unit Commands / Queries CODE PAGE CODE PAGE CODE PAGE CODE Q PAGE CODE PAGE 7–24 7–23 7–26 7–27 7–30 7–30 7–24 7–26 7–28 7–30 7–30 7–24 7–26 7–28 7–30 7–23 7–24 7–27...
  • Page 103 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Sect. 7.5.8 Gigabit Ethernet Interface Commands / Queries CODE PAGE CODE PAGE 7–36 7–36 Sect. 7.5.9 ODU Commands / Queries CODE PAGE CODE PAGE CODE PAGE CODE PAGE 7–37 7–37 7–37 7–37 7–38 7–37 7–37 NOTE –...
  • Page 104 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Serial Remote Control 7–10 MN-SLM-5650C...
  • Page 105: Initial Setup - Priority Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.2 Initial Setup – Priority Commands / Queries Before executing any Modem, Unit, Bulk/Global, AUPC, or Optional Interface commands/queries, initial setup should be accomplished with these three commands, prioritized as follows: (Highest Priority) MOM, RFB, ITF (Lowest Priority). Priority commands are indicated by shading throughout these sections.
  • Page 106: Modulator (Tx) Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.3 Modulator (Tx) Commands / Queries Tx Priority System = (Highest priority) TFM, TFT, TMD, TCR, and TDR (Lowest Priority). Priority commands indicated by . Any shading change to a higher priority parameter can override any of the parameters of lower priority. Command Arguments for Query...
  • Page 107 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) Tx Code TCR= 1 byte Command or Query TCR= TCR?
  • Page 108 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) Tx Clock TCI= 1 byte Command or Query.
  • Page 109 Arguments) 1 = OM-73 Scrambler TSC# 2 = V.35 Scrambler 3 = Modified V.35 (Comtech EF Data Closed Network) 4 = Reed-Solomon Synchronous Scrambler 5 = IBS Overhead Synchronous Scrambler 6 = TURBO Scrambler Depending on Modem mode, FEC type, overhead type, and RS state, not all selections will be valid.
  • Page 110 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) TSF= 4 bytes Command or Query. TSF= TSF? TSF=xxxx...
  • Page 111: Demodulator (Rx) Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.4 Demodulator (Rx) Commands / Queries Rx Priority System = (Highest priority) RFM, RFT, RMD, RCR, and RDR (Lowest Priority). Priority commands are indicated by . Any shading change to a higher priority parameter can override any of the parameters of lower priority. Command Arguments for Query...
  • Page 112 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) Rx FEC RCR= 1 byte Command or Query.
  • Page 113 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) Rx BERT BTH= 1 byte Command or Query.
  • Page 114 Arguments) 1 = OM-73 Scrambler RDS# 2 = IESS-V.35 Scrambler 3 = Modified V.35 (Comtech EF Data Closed Network) 4 = Reed-Solomon Synchronous Scrambler 5 = IBS Overhead Synchronous Scrambler 6 = TURBO Scrambler Depending on Modem mode, FEC type, overhead type, and RS state, not all selections will be valid.
  • Page 115 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) RRD= 1 byte Command or Query. RRD = RRD? RRD =x...
  • Page 116 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Response to Description of Arguments Type Code and Response to Command Code and Query Qualifier) Query Qualifier) Rx Demod RSW= 8 bytes Command or Query.
  • Page 117: Modem, Unit Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.5 Modem, Unit Commands / Queries Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Clear All CAE=...
  • Page 118 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Configured h = Vipersat Data Rate Option: FAST 0 = Base (5,000 kbps), Options...
  • Page 119 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Equipment ID N/A 17 bytes Query only.
  • Page 120 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Equipment ID h = Transec: (Continued) 0 = None 1 = Transec Installed...
  • Page 121 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Initialize ISP= None Command only. ISP= Statistics Resets internal pointer to allow RNS? queries to start at the beginning of...
  • Page 122 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Number of 3 bytes Query only. NUE? NUE=xxx Unread...
  • Page 123 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Retrieve next 110 bytes Query only. RNE? RNE={CR}Axxxxxxxxddmmyyhhmmss 5 unread...
  • Page 124 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Statistics SSI= 1 byte Command or Query. SSI= SSI? SSI=x...
  • Page 125: Bulk Configuration Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.6 Bulk Configuration Commands / Queries Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) Configuration CLD=...
  • Page 126: Automatic Uplink Power Control (Aupc) Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.7 Automatic Uplink Power Control (AUPC) Commands / Queries The instruction codes that follow are valid only when the SLM-5650C Satellite Modem type has been set to AUPC. Note: Always wait three (3) seconds between consecutive remote modem command/query polls. If Local AUPC is not enabled, queries will return the last known condition.
  • Page 127 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Query Arguments Parameter (Instruction for Command Response to (Instruction Description of Arguments Response to Query Type Code and or Response Command Code and to Query Qualifier) Qualifier) AUPC Log ASI= 1 byte Command or Query.
  • Page 128 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Query Arguments Parameter (Instruction for Command Response to (Instruction Description of Arguments Response to Query Type Code and or Response Command Code and to Query Qualifier) Qualifier) Retrieve next 155 bytes Query only. RNA? RNA= 5 unread...
  • Page 129 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Query Arguments Parameter (Instruction for Command Response to (Instruction Description of Arguments Response to Query Type Code and or Response Command Code and to Query Qualifier) Qualifier) Remote RPL= 1 byte Command or Query. RPL= RPL? RPL=x...
  • Page 130: Gigabit Ethernet Interface Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.8 Gigabit Ethernet Interface Commands / Queries The instruction codes that follow are valid only when the internal 10/100/1000 BaseT Gigabit Ethernet Interface is installed in the SLM-5650C Satellite Modem. Command Arguments for Query Parameter (Instruction...
  • Page 131: Odu Commands / Queries

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 7.5.9 ODU Commands / Queries The instruction codes that follow control 10 MHz references and power for Outdoor Units. Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and...
  • Page 132 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Command Arguments for Query Parameter (Instruction Command or Response to (Instruction Description of Arguments Response to Query Type Code and Response to Command Code and Qualifier) Query Qualifier) LNB Current 3 bytes Query only. LNC? LNC=xxx Monitor...
  • Page 133: Chapter 8. 10/100/1000Base-T (Gbe) Interface

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Chapter 8. 10/100/1000BASE-T (GbE) INTERFACE Introduction This chapter applies to both the SLM-5650C and the SLM-5650C-ODU. The 10/100/1000BASE-T Ethernet – or Gigabit Ethernet (GbE) – Interface acts as an Ethernet bridge for data traffic. IP traffic entering the GbE Interface is encapsulated in HDLC protocol for transmission over the satellite link.
  • Page 134: Connector Pinout

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 8.2.1 Connector Pinout The GbE Interface is comprised of one IEEE 802.3ab 1000Base-T copper interface via a single ‘RJ-45’ type female connector. The LAN interface supports 10/100/1000BASE-T operation. Table 8-1. Connector Pinout Pin # Description Direction BI_DA+...
  • Page 135: Appendix A. Troubleshooting

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Appendix A. TROUBLESHOOTING Overview This appendix applies to both the SLM-5650C and the SLM-5650C-ODU. This appendix provides information pertaining to the modem’s system checkout and fault isolation and identification. Common Setup Issues Check the following items if you encounter setup issues: •...
  • Page 136: Initial System Check

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.1 Initial System Check Use the Modem Status page to check the modem's operational link. Current fault events are displayed along with the receive signal level, Eb/No, Rx Frequency Offset, etc. The modem status LEDs provide a visual indication for the status of the modem. •...
  • Page 137: A.3.1.2 Slm-5650C-Odu Status Indicators

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 The following table describes the LED conditions: Table A-2. SLM-5650C LED Conditions Comment LED Rx LOCK LED Tx PWR ON LED PWR/ FAULT No faults Green Green Green blinking Rx signal in Tx on No Receive Off, occasional blink* Green...
  • Page 138: Table A-4. Slm-5650C-Odu Led Conditions

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 The following table describes the LED conditions: Table A-4. SLM-5650C-ODU LED Conditions Comment LED Rx LOCK LED Tx PWR ON LED FAULT No faults Green Green Green blinking Rx signal in Tx on No Receive Off, occasional blink* Green...
  • Page 139: System Check Using If Loopback And Internal Bert

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.2 System Check Using IF Loopback and Internal BERT The modem can be tested independently using IF loopback and the Internal BERT. Step Task Turn off IF loopback before changing Modem Types. Reset the modem configuration to Modem Type defaults. Change the Modem Type to a selection other than your desired test selection.
  • Page 140: A.3.2.1 Tx Waveform Check

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.2.1 Tx Waveform Check Step Task Use a spectrum analyzer to check the Tx modulated waveform. Figure A-4 shows proper waveform output of the Tx RF path for block up converters, splitters, or high-powered amplifiers.
  • Page 141: A.3.2.2 Rx Waveform Check

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.2.2 Rx Waveform Check Step Task Use a spectrum analyzer to check the Rx modulated waveform. The Rx waveform displays the following when receiving a signal from a satellite system: A raised noise floor that obscures the low shoulders, similar to Figure A-4. A flat top without any slope or distortion.
  • Page 142: Modem Demodulator Constellations

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 A.3.3 Modem Demodulator Constellations View the modem demodulator constellations by using the IQ Mon application on the user computer. The IQ Mon uses the modem ethernet management connection to retrieve the constellation information. Typical constellation patterns are shown in Figure A-5 through Figure A-10. Error Vector Magnitude (EVM) is a measure of how far the points are from the ideal quadrature locations.
  • Page 143: Figure A-7. Oqpsk Constellation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Figure A-7. OQPSK Constellation Figure A-8. 8QAM Constellation Appendix A A–9 MN-SLM-5650C...
  • Page 144: Figure A-9. 16Qam Constellation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Figure A-9. 16QAM Constellation Figure A-10. 8PSK Constellation Appendix A A–10 MN-SLM-5650C...
  • Page 145: Fault Isolation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Fault Isolation Faults are displayed on the Modem Status page and the Modem Event Log page. They are in Hexadecimal format and are hyperlinked to a description. Click on the fault code and a pop up will show the fault condition.
  • Page 146 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Appendix A A–12 MN-SLM-5650C...
  • Page 147: Appendix B. Operations Reference

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Appendix B. OPERATIONS REFERENCE Overview This appendix applies to both the SLM-5650C and the SLM-5650C-ODU. It provides the end user with reference guides for the DSSS and non-DSSS LDPC modes. The Data Rates and Symbol Rates shown in the following tables all assume that Transmission Security (TRANSEC) is turned OFF.
  • Page 148: Om-73 Mode

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 B.1.1 OM-73 Mode Data Rate (kbps) Symbol Rate (ksps) Modulation Type BPSK 1/1 8472 10000 BPSK 1/2 15000 30000 BPSK 3/4 22500 85.333 29999.999 BPSK 7/8 26250 73.142 30000 QPSK 1/1 20000 10000 QPSK 1/2 30000 30000...
  • Page 149 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) R-S Code Modulation Type R-S Depth Word BPSK 1/2 220,200 4, 8 13636.363 140.8 30000 BPSK 3/4 126,112 4, 8 20000 29999.999 BPSK 3/4 219,201 4, 8 20650.684 92.975 29999.998...
  • Page 150: Mil-Std-188-165A Mode - Sequential

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) R-S Code Modulation Type R-S Depth Word 8-PSK 5/6 126,112 4, 8 51840 115.2 23328 8-PSK 5/6 219,201 4, 8 51840 111.57 22592.955 8-PSK 5/6 225,205 4, 8 51840 112.39 22759.024...
  • Page 151: Iess-308 Mode - Standard Higher Rates

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) Modulation Type R-S Code Word Depth OQPSK 3/4 220,200 3409.090 46.933 2500 OQPSK 7/8 4375 36.571 2500 OQPSK 7/8 126/112 3888.888 41.142 2500 OQPSK 7/8 219,201 4015.410 39.846 2500 OQPSK 7/8...
  • Page 152 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 R-S Code Data Rate Symbol Rate Modulation Type Overhead R-S Depth Word (kbps) (ksps) QPSK 3/4 IESS-308 8448 5632 QPSK 3/4 IESS-308 32064 21376 QPSK 3/4 IESS-308 34368 22912 QPSK 3/4 IESS-308 44736 29824 QPSK 3/4 IESS-308...
  • Page 153 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 R-S Code Data Rate Symbol Rate Modulation Type Overhead R-S Depth Word (kbps) (ksps) QPSK 7/8 IESS-308 8448 4827.428 QPSK 7/8 IESS-308 32064 20040.571 QPSK 7/8 IESS-308 34368 21473.714 QPSK 7/8 IESS-308 44736 27922.857 QPSK 7/8 IESS-308...
  • Page 154: Iess-308 Mode - Extended

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 R-S Code Data Rate Symbol Rate Modulation Type Overhead R-S Depth Word (kbps) (ksps) QPSK 7/8 IESS-308 208,192 4, 8, 16 34368 21473.714 QPSK 7/8 IESS-308 208,192 4, 8, 16 44736 27922.857 B.1.5 IESS-308 Mode –...
  • Page 155 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) Modulation R-S Code Overhead Type Word Depth QPSK 7/8 IESS-309 126,112 4, 8, 16 8448 43.886 5792.914 QPSK 7/8 IESS-309 219,201 4, 8, 16 8448 42.503 5610.385 QPSK 7/8 IESS-309 194,178...
  • Page 156: Iess-309 Mode - Extended (Closed Network

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) Modulation R-S Code Overhead Type Word Depth OQPSK 7/8 IESS-309 219,201 4, 8, 16 8448 42.503 5610.385 OQPSK 7/8 IESS-309 194,178 4, 8, 16 8448 42.516 5612.112 OQPSK 7/8 IESS-309 225,205...
  • Page 157: Iess-310 Mode - Extended Rates

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 B.1.7 IESS-310 Mode – Extended Rates Modulation R-S Code Overhead R-S Depth Data Rate (kbps) Symbol Rate (ksps) Type Word 8-PSK 2/3 None 219,201 4, 8, 16 139.463 8-PSK 2/3 None 219,201 4, 8, 16 51840 28241.194 8-PSK 2/3...
  • Page 158: 16-Qam Mode

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 B.1.9 16-QAM Mode Data Rate (kbps) Symbol Rate (ksps) R-S Code Modulation Type R-S Depth Word 16-QAM 3/4 None None 51840 85.333 17280 16-QAM 3/4 219,201 4, 8, 16 51840 92.975 18827.462 16-QAM 3/4 208,192 4, 8, 16 51840...
  • Page 159: Aupc Mode - Sequential

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Data Rate (kbps) Symbol Rate (ksps) Modulation Type R-S Code Word R-S Depth OQPSK 1/2 225,205 25625 74.926 30000 OQPSK 3/4 225,205 38437.500 49.951 30000 OQPSK 7/8 225,205 44843.750 42.815 30000 8PSK 2/3 225,205 51250 149.853...
  • Page 160: Aupc Mode - Turbo

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 B.1.12 AUPC Mode – Turbo Data Rate (kbps) Symbol Rate (ksps) Modulation Type BPSK 21/44 13423.295 143.034 29999.998 BPSK 5/16 8789.062 218.453 29999.998 QPSK 17/18 51840 36.141 29274.352 QPSK 21/44 26846.590 71.517 29999.998 QPSK 3/4 42187.500 45.511...
  • Page 161: Non-Spread Ldpc Mode - Low Latency (Ll

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 B.1.14 NON-SPREAD LDPC Mode – Low Latency (LL) Data Rate (kbps) Symbol Rate (ksps) DR to SR Modulation Type Multiplier BPSK .378 32.000 5000 84.676 13230.769 4128/1560 BPSK .451 32.000 5000 71.019 11096.774 4128/1860 BPSK .541 32.000...
  • Page 162 SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 BLANK PAGE Appendix B B–16 MN-SLM-5650C...
  • Page 163: Appendix C. Overhead And Symbol Rate Calculations

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Appendix C. OVERHEAD and SYMBOL RATE CALCULATIONS Overview This appendix applies to both the SLM-5650C and the SLM-5650C-ODU. The modem has several optional features and functions that can add overhead. This appendix describes: •...
  • Page 164: Processing Flow And Symbol Rate Calculation

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Processing Flow and Symbol Rate Calculation The modem supports Ethernet interface and provides options for framing, modulation and spreading. Figure C-1 shows the processing flow for these functions. Figure C-1. SLM-5650C/ SLM-5650C-ODU – Feature Block Diagram The symbol rate (Carrier 3dB Bandwidth) is a function of the programmed data bit rate with...
  • Page 165: Sources Of Overhead

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 Sources of Overhead C.3.1 Framing Overhead Several modes of operation add framing overhead to the satellite channel. C.3.1.1 AUPC Framing AUPC overhead channel is referred to as “Operand 3” in Section C.2: • The AUPC communications channel also supports modem-to-modem receiver signal Eb/No status used to automatically adjust the Tx uplink power when (AUPC Power Control) is enabled.
  • Page 166: Product Support

    SLM-5650C / SLM-5650C-ODU Satellite Modem Revision 1 See RFC 4814 “Hash and Stuffing: Overlooked Factors in Network Device Benchmarking” for a derivation of this probability. Considering both sources of HDLC Overhead means that, for a packet length “ ”, the ratio of input bits to encapsulated output bits is expressed as “Equation 2”: =L/[L+3+L/62] = L/[(63/62)L+3] Unlike framing overhead, HDLC Overhead reduces the effective throughput of packet bits relative...