SLM-5650A Satellite Modem
Front Panel Operation
5.2.7.3
Utility: ID
Edit Circuit ID:
------------------------
Use the arrow keys to name the communications link. This name can be any
combination of alphanumeric characters up to 24 characters in length.
Additional characters supported are: ( ) * + / . (period) , (comma) and space.
5.2.7.4
Utility: Display
Edit Display Brightness
100%
Use the arrow keys to adjust the front panel display brightness. Valid settings are 25%,
50%, 75% or 100%.
5.2.7.5
Utility: Temp
Modem Temp (Deg C): RF=+61
This read-only screen allows the user to view the modem internal temperatures (RF, PS, M&C,
Mod and Demod).
5.2.7.6
Utility: AGC
AgcMan:
Use the arrow keys to select, and then set the Minimum and Maximum voltage levels
for the external AGC monitor voltage that is available on the AUX connector.
Option
Min Value
Max Value
M&C=+35
Mod=+43
Min Value: 00.0 Volts
Max Value: 10.0 Volts (E)
Setting
Specifies the voltage to output on the External AGC voltage signal when the demodulator RSL
is at its minimum level.
Specifies the voltage to output when the demodulator RSL is at its maximum level.
(E)
(E)
PS=+40
Demod=+51
5–44
Revision 8
MN-SLM5650A
(E)