configure fdb-scan period

configure fdb-scan period <period <1-60>>
Description
Configures the amount of time between FDB scans.
Syntax Description
period <1-60>
Default
30 seconds.
Usage Guidelines
If you configure a timer interval of less than 15 seconds, the following warning message is displayed
and you are asked to confirm the change:
Setting period below (15) may starve other tasks.
Do you wish to do this? (yes, no, cancel) 06/19/2003 10:29.28 <INFO:SYST> serial
admin: configure fdb-scan period 1
n
Extreme Networks recommends an interval period of at least 15 seconds.
This setting is independent of and does not affect the system health check configurations.
Example
The following command configures a timer interval of 20 seconds between FDB scans:
configure fdb-scan period 20
History
This command was first available in ExtremeWare 6.2.2b108.
This command was not supported in ExtremeWare 7.0.
This command is supported in ExtremeWare 7.1.0.
Platform Availability
This command is available on all platforms.
ExtremeWare Software 7.3.0 Command Reference Guide
Specifies the timer interval, in seconds, between FDB scans. The range is 1 to
60 seconds.
configure fdb-scan period