Extreme Networks ExtremeWare Command Reference Manual page 657

Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

configure sys-recovery-level
For ExtremeWare 6.2.2 or later, if
is specified on a BlackDiamond switch and there is a
msm-failover
software exception on the master MSM, the interrupt handler triggers the slave MSM to take over
control of the switch.
Example
The following command configures a switch to reboot after a critical task exception occurs:
configure sys-recovery-level critical reboot
The following command configures the Master MSM to failover to the Slave MSM if a software
exception occurs:
configure sys-recovery-level critical msm-failover
History
This command was first available in ExtremeWare 6.1.
Modified in ExtremeWare 6.2 to support the
and
options.
shutdown
reboot
Modified in ExtremeWare 6.2.2 to support the
option.
msm-failover
Platform Availability
This command is available on all i-series switches. The
option is available on
msm-failover
BlackDiamond switch only.
ExtremeWare Software 7.3.0 Command Reference Guide
657