Commands for Status Monitoring and Statistics
Example
By default, all log targets are associated with the built-in filter, DefaultFilter. Therefore, the most
straightforward way to send additional messages to a log target is to modify DefaultFilter. In the
following example, the command modifies the built-in filter to allow incidents in the STP component,
and all subcomponents of STP, of severity critical, error, warning, notice and info. For any of these
events containing a physical port number as a match parameter, limit the incidents to only those
occurring on physical ports 3, 4 and 5 on slot 1, and all ports on slot 2:
configure log DefaultFilter add events stp severity info match ports 1:3-1:5, 2:*
If desired, issue the
command to restore the DefaultFilter back to its
unconfigure log DefaultFilter
original configuration.
History
This command was first available in ExtremeWare 7.1.0.
Platform Availability
This command is available on all platforms.