configure ports redundant
• Software redundant ports are not supported on 1000BASE-T ports.
Software redundant port only cover failures where both the TX and RX paths fail. If a single strand of
fiber is pulled, the software redundant port cannot correctly recover from the failure.
Example
The following command configures a software-controlled redundant port on a stand-alone switch:
configure ports 3 redundant 4
The following command configures a software-controlled redundant port on a modular switch:
configure ports 1:3 redundant 2:3
The following command configures a software-controlled redundant port using the port display strings
corp1 and corp5 to identify the ports:
configure ports corp1 redundant corp5
History
This command was first available in ExtremeWare 6.2.
Platform Availability
This command is available on all platforms.
ExtremeWare Software 7.3.0 Command Reference Guide
247