Extreme Networks ExtremeWare Command Reference Manual page 247

Hide thumbs Also See for ExtremeWare:
Table of Contents

Advertisement

configure ports redundant
• Software redundant ports are not supported on 1000BASE-T ports.
Software redundant port only cover failures where both the TX and RX paths fail. If a single strand of
fiber is pulled, the software redundant port cannot correctly recover from the failure.
Example
The following command configures a software-controlled redundant port on a stand-alone switch:
configure ports 3 redundant 4
The following command configures a software-controlled redundant port on a modular switch:
configure ports 1:3 redundant 2:3
The following command configures a software-controlled redundant port using the port display strings
corp1 and corp5 to identify the ports:
configure ports corp1 redundant corp5
History
This command was first available in ExtremeWare 6.2.
Platform Availability
This command is available on all platforms.
ExtremeWare Software 7.3.0 Command Reference Guide
247

Advertisement

Table of Contents
loading

This manual is also suitable for:

Extremeware 7.3.0

Table of Contents