Fibre Channel Time Out Values
You can modify Fibre Channel protocol related timer values for the switch by configuring the following
time out values (TOVs):
The fabric stability TOV (F_S_TOV) constant cannot be configured.
Note
This section includes the following topics:

Timer Configuration Across All VSANs

You can modify Fibre Channel protocol related timer values for the switch.
Caution
The D_S_TOV, E_D_TOV, and R_A_ TOV values cannot be globally changed unless all VSANs in the
switch are suspended.
If a VSAN is not specified when you change the timer value, the changed value is applied to all VSANs
Note
in the switch.
Cisco MDS 9000 Family Fabric Manager Configuration Guide
37-2
The certificate file contains the certificate and the private key.
The private key must be RSA type.
The certificate file should be in PEM (Private Electronic Mail) style format and have .pem as the
extension.
-----BEGIN CERTIFICATE-----
(certificate goes here)
-----END CERTIFICATE-----
-----BEGIN RSA PRIVATE KEY-----
(private key goes here)
-----END RSA PRIVATE KEY-----
Distributed services TOV (D_S_TOV)—The valid range is from 5,000 to 10,000 milliseconds. The
default is 5,000 milliseconds.
Error detect TOV (E_D_TOV)—The valid range is from 1,000 to 10,000 milliseconds. The default
is 2,000 milliseconds. This value is matched with the other end during port initialization.
Resource allocation TOV (R_A_TOV)—The valid range is from 5,000 to 10,000 milliseconds. The
default is 10,000 milliseconds. This value is matched with the other end during port initialization.
Timer Configuration Across All VSANs, page 37-2
Timer Configuration Per-VSAN, page 37-3
About fctimer Distribution, page 37-4
Enabling or Disabling fctimer Distribution, page 37-4
Database Merge Guidelines, page 37-5
Chapter 37
Advanced Features and Concepts
OL-17256-03, Cisco MDS NX-OS Release 4.x

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents