Chapter 59
Configuring RMON
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

Enabling 32-bit RMON Alarms for VSANs

To enable an RMON alarm for one or more VSANs using Device Manager, follow these steps:
Choose Admin > Events > Threshold Manager and click the Services tab.
Step 1
You see the Threshold Manager dialog box.
Click the Services tab.
Step 2
You see the Threshold Manager dialog box with the Services tab for 32-bit alarm selecte as shown in
Figure
Figure 59-8
Click on the 32-bit radio button.
Step 3
Enter one or more VSANs (multiple VSANs separated by commas) to monitor in the VSAN ID(s) field.
Step 4
Use the down arrow to see a list of available VSANs to choose from.
Check the check box in the Select column for each variable to monitor.
Step 5
Enter the threshold value in the Value column.
Step 6
Enter the sampling period in seconds.
Step 7
Choose a severity level to assign to the alarm: Fatal, Critical, Error, Warning, Information.
Step 8
Click Create.
Step 9
Confirm the operation to define an alarm and a log event when the system prompts you to define a
Step 10
severity event.
If you do not confirm the operation, the system only defines a log event.
Click More, then click the Alarms tab in the Threshold Manager dialog box to verify the alarm you
Step 11
created.
OL-17256-03, Cisco MDS NX-OS Release 4.x
59-8.
Services Tab for 32-Bit Alarm Dialog Box
Create RMON Alarms in Fabric Manager