Manual IVR Configuration
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
Expand All VSANs and then select IVR in the Logical Domains pane.
Step 1
You see the IVR configuration in the Information pane.
Figure 29-12
Click the FCID tab.
Step 2
Click the Create Row icon to create an FC ID (see
Step 3
Select the switch for which you are configuring the virtual FC ID to be used to represent a device in a
Step 4
specific VSAN (current VSAN).
Enter the current fabrc in the Current Fabric ID field for the fcdomain database.
Step 5
Enter the current VSAN in the Current VSAN ID field for the fcdomain database.
Step 6
Enter the pWWN.
Step 7
Step 8
Click the drop-down menu to select the FC ID to map to the pWWN you selected.
Step 9
Click Create to create this new row.

Configuring IVR Logging Levels

To configure the severity level for logging messages from the IVR feature using Fabric Manager, follow
these steps:
Expand Switches > Events and then select Syslog from the Physical Attributes pane.
Step 1
Click the Severity Levels tab.
Step 2
Click the Facility column header to sort the table by facility name.
Step 3
Select the severity level at which the IVR logs system messages from the Severity drop-down menu (see
Step 4
Figure
Cisco MDS 9000 Family Fabric Manager Configuration Guide
29-20
FCID Tab
29-13).
Chapter 29
Configuring Inter-VSAN Routing
Figure
29-12).