t1 fdl string
t1 channel fdl string { eic eicValue | fic ficValue | lic licValue | unit unitValue |
Syntax
pfi pfiValue | port portValue | generator generatorValue }
no t1 channel fdl string { eic | fic | lic | unit | pfi | port | generator }
Command introduced before JUNOSe Release 7.1.0.
Release Information
Defines an FDL message on a T1 channel on a CT3 interface as defined in the ANSI
Description
T1.403 specification. Currently, FDL strings can be configured only locally. The no
version restores the default value to the specified FDL message or to all FDL messages.
Options
Controller Configuration
Mode
channel One or more individual T1 channels, ranges of T1 channels, or
combination of individual channels and ranges, in the range 1–28 (no spaces);
for example, 3,7-15,19-13,27
eicValue Equipment identification code; 1–10 characters; default value is the
null value
ficValue Frame identification code; 1–10 characters; default value is the null
value
licValue Line identification code; 1–10 characters; default value is the null value
unitValue Unit identification code; 1–6 characters; default value is the null value.
pfiValue Facility identification code to send in the FDL path message; 1–38
characters; default value is the null value.
portValue Equipment port number to send in the FDL idle signal message; 1–38
characters; default value is the null value.
generatorValue Generator number to send in the FDL test signal message; 1–38
characters; default value is the null value.
Chapter 8: T Commands
1257
t1 fdl string