Command System
Executing this command will overwrite the current duty cycle setting
[:SOURce[<n>]]:FUNCtion:SQUare:DCYCle
(
square wave.
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
None.
Examples
:SOURce1:APPLy:SQUare 100,5,0.5,3 /*Sets CH1 to output a square
wave with 100 Hz frequency, 5 Vpp amplitude, 0.5 Vdc offset, and
3° start phase.*/
3.11.3
[:SOURce[<n>]]:ASKey
[:SOURce[<n>]]:ASKey commands are used to set and query ASK parameters such
as the modulation amplitude, modulation rate, modulation polarity, modulation
source, and the on/off status of the ASK modulation function.
3.11.3.1
[:SOURce[<n>]]:ASKey:AMPLitude
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the ASK modulation amplitude for the specified channel.
Parameter
Name
<n>
<amplitude>
<lim_set>
<lim_query>
Remarks
In ASK modulation, the instrument shift its output amplitude between two
preset values (called the carrier amplitude and the modulation amplitude).
The range of <amplitude> is consistent with the amplitude range of basic
waveforms (
DG800 Pro/DG900 Pro Programming
Guide
76
n >]]:ASKey:AMPLitude {< amplitude >|< lim_set >}
n >]]:ASKey:AMPLitude? [< lim_query >]
Type
Range
Discrete
{1|2}
Real
Refer to
Discrete
{MINimum|MAXimum|DEFault}
Discrete
{MINimum|MAXimum}
Table 3.62 Range of Amplitude
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.