Command System
Examples
:DISPlay:COUNter PERiod /*Sets the currently displayed measurement
parameter to period for counter measurements.*/
:DISPlay:COUNter? /*Queries the currently displayed measurement
parameter for counter measurements. The query returns PER.*/
3.3.3
:DISPlay:FOCus
Syntax
:DISPlay:FOCus <
:DISPlay:FOCus?
Description
Sets or queries the current channel.
Parameter
Name
<chan>
Remarks
As DG821 Pro has one channel, it only supports CH1 by default (unless the two-
channel upgrade option is installed).
Return Format
The query returns CH1 or CH2.
Examples
:DISPlay:FOCus CH1 /*Sets the current channel to CH1.*/
:DISPlay:FOCus? /*Queries the current channel. The query returns
CH1.*/
3.3.4
:DISPlay[:STATe]
Syntax
:DISPlay[:STATe] <
:DISPlay[:STATe]?
Description
Enables or disables the front-panel screen. Queries the current state of the front-panel
screen.
DG800 Pro/DG900 Pro Programming
Guide
18
chan >
Type
Range
Discrete
{CH1|CH2}
bool >
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
CH1