Command System
•
You can use
sync signal.
•
When [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns 0 or 1.
Examples
:OUTPut1:SYNC ON /*Enables the sync signal output.*/
:OUTPut1:SYNC? /*Queries the output state of the sync signal. The
query returns 1.*/
3.10.6
:OUTPut[<n>]:SYNC:MODE
Syntax
:OUTPut[<
:OUTPut[<
Description
Sets or queries whether the frequency mark function is enabled for the specified
channel.
Parameter
Name
<n>
<mode>
Remarks
•
NORMal: disables the frequency mark function.
•
MARKer: enables the frequency mark function.
•
This function can be enabled only when the Sweep function
(
[:SOURce[<n>]]:SWEep:STATe
•
When [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns NORM or MARK.
Examples
:OUTPut1:SYNC:MODE MARKer /*Enables the frequency mark function for
CH1.*/
DG800 Pro/DG900 Pro Programming
Guide
58
:OUTPut[<n>]:SYNC:SOURce
n >]:SYNC:MODE < mode >
n >]:SYNC:MODE?
Type
Discrete
Discrete
to select the output terminal of the
Range
{1|2}
{NORMal|MARKer}
) is enabled for the specified channel.
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
1
NORMal