Command System
Parameter
Name
<type>
Remarks
•
STARtstop: uses the start value (
value (
•
CENTerspan: uses the middle value (
span (
Return Format
The query returns STAR or CENT.
Examples
:DISPlay:UNIT:SWEep CENTerspan /*Uses the middle value and span to
specify the frequency sweep range.*/
:DISPlay:UNIT:SWEep? /*Queries the method to specify the frequency
sweep range. The query returns CENT.*/
3.3.10
:DISPlay:UNIT:VOLTage
Syntax
:DISPlay:UNIT:VOLTage <
:DISPlay:UNIT:VOLTage?
Description
Sets or queries the method to specify the voltage range.
Parameter
Name
<type>
Remarks
•
AMPLitudeoff: uses the amplitude (
[:SOURce[<n>]]:VOLTage:OFFSet
(
•
HIGHlow: uses the high level (
[:SOURce[<n>]]:VOLTage:LOW
(
Return Format
The query returns AMPL or HIGH.
DG800 Pro/DG900 Pro Programming
Guide
22
Type
Discrete
[:SOURce[<n>]]:FREQuency:STOP
[:SOURce[<n>]]:FREQuency:SPAN
type >
Type
Discrete
Range
{STARtstop|CENTerspan}
[:SOURce[<n>]]:FREQuency:STARt
) to specify the frequency sweep range.
[:SOURce[<n>]]:FREQuency:CENTer
) to specify the frequency sweep range.
Range
{AMPLitudeoff|HIGHlow}
[:SOURce[<n>]]:VOLTage
) to specify the voltage range.
[:SOURce[<n>]]:VOLTage:HIGH
) to specify the voltage range.
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
STARtstop
) and stop
) and
Default
AMPLitudeoff
) and offset
) and low level