Command System
:SOURce1:HARMonic:ORDer? /*Queries the order of the order harmonic
for CH1. The query returns 10.*/
3.11.9.5
[:SOURce[<n>]]:HARMonic:ORDEr:AMPLitude
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the amplitude of the specified order of order harmonic for the
specified channel.
Parameter
Name
<amplitude>
<lim_set>
<lim_query>
Remarks
•
The amplitude upper limit of the specified channel is limited by the impedance
setting (
•
You can use
order harmonic for the specified channel.
•
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns the harmonic amplitude in scientific notation. For example, the
query might return 1.000000E+00, indicating that the harmonic amplitude is 1 Vpp.
Examples
:SOURce1:HARMonic:ORDEr:AMPLitude 1 /*Sets the amplitude of the
current order of order harmonic to 1 Vpp for CH1.*/
:SOURce1:HARMonic:ORDEr:AMPLitude? /*Queries the amplitude of the
current order of order harmonic for CH1. The query returns
1.000000E+00.*/
3.11.9.6
[:SOURce[<n>]]:HARMonic:ORDEr:PHASe
Syntax
[:SOURce[<
DG800 Pro/DG900 Pro Programming
Guide
122
n >]]:HARMonic:ORDEr:AMPLitude {< amplitude >|< lim_set >}
n >]]:HARMonic:ORDEr:AMPLitude? [< lim_query >]
Type
Range
2 mVpp (HighZ) to the amplitude upper
Real
limit of the specified channel
Discrete
{MINimum|MAXimum|DEFault}
Discrete
{MINimum|MAXimum}
:OUTPut[<n>]:LOAD
) and frequency/period setting.
[:SOURce[<n>]]:HARMonic:ORDer
n >]]:HARMonic:ORDEr:PHASe {< phase >|< lim_set >}
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
5 Vpp
-
-
to set or query the order of the