Command System
Remarks
The harmonic type can be set to the following:
-
-
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns ORD or COMB.
Examples
:SOURce1:HARMonic:TYPE ORDer /*Sets the harmonic type to order
harmonic for CH1.*/
:SOURce1:HARMonic:TYPE? /*Queries the harmonic type for CH1. The
query returns ORD.*/
3.11.10
[:SOURce[<n>]]:MARKer:FREQuency
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the mark frequency for the specified channel.
Parameter
Name
<n>
<frequency>
<lim_set>
<lim_query>
Remarks
The parameter <frequency> is limited by the sweep "Start Frequency"
[:SOURce[<n>]]:FREQuency:STARt
(
[:SOURce[<n>]]:FREQuency:STOP
(
stop frequency.
DG800 Pro/DG900 Pro Programming
Guide
124
ORDer: order harmonic which outputs the basic waveform and a single
[:SOURce[<n>]]:HARMonic:ORDer
harmonic component (
COMBine: combine harmonic which outputs harmonics with multiple
harmonic components. You can self-define the orders of harmonic
[:SOURce[<n>]]:HARMonic:COMBine
(
n >]]:MARKer:FREQuency {< frequency >|< lim_set >}
n >]]:MARKer:FREQuency? [< lim_query >]
Type
Discrete
Real
Discrete
Discrete
). The maximum order is 20.
Range
{1|2}
Remarks
Refer to
{MINimum|MAXimum|DEFault}
{MINimum|MAXimum}
) and "Stop Frequency"
). It must lie between the start frequency and