Counter:coupling; Counter[:Frequency]:Range - Rigol DG800 Pro Series Programming Manual

Function/arbitrary waveform generator
Hide thumbs Also See for DG800 Pro Series:
Table of Contents

Advertisement

Command System
Examples
:COUNter:AVERage:STATe ON /*Enables the statistical function for
the frequency counter.*/
:COUNter:AVERage:STATe? /*Queries the on/off status of the
statistical function for the frequency counter. The query returns
1.*/
3.2.4

:COUNter:COUPling

Syntax
:COUNter:COUPling <
:COUNter:COUPling?
Description
Sets or queries the coupling type of input signals for counter measurements.
Parameter
Name
<coupling>
Remarks
AC: AC coupling. It is available only when the input impedance
:COUNter:IMPedance
(
DC: DC coupling.
Return Format
The query returns AC or DC.
Examples
:COUNter:COUPling DC /*Sets the coupling type to DC for counter
measurements.*/
:COUNter:COUPling? /*Queries the coupling type for counter
measurements. The query returns DC.*/
3.2.5

:COUNter[:FREQuency]:RANGe

Syntax
:COUNter[:FREQuency]:RANGe <
:COUNter[:FREQuency]:RANGe?
Description
Sets or queries the frequency range for counter measurements.
DG800 Pro/DG900 Pro Programming
Guide
10
coupling >
Type
Range
Discrete
{AC|DC}
) is set to 1 MΩ.
range >
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Default
AC

Advertisement