Command System
Return Format
If querying the specified harmonic, the query returns the amplitude of the specified
order of combine harmonic, for example, 1.000000E +00. If querying the amplitudes
of all orders of the harmonic (ALL), the query returns all amplitudes separated by
commas.
Examples
:SOURce1:HARMonic:COMBine:AMPLitude 5,1 /*Sets the amplitude of
the 5th order of harmonic to 1 Vpp for CH1.*/
:SOURce1:HARMonic:COMBine:AMPLitude? 5 /*Queries the amplitude of
the 5th order of harmonic for CH1. The query returns 1.000000E
+00.*/
3.11.9.3
[:SOURce[<n>]]:HARMonic:COMBine:PHASe
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the phase of the specified order of combine harmonic for the
specified channel.
Parameter
Name
<n>
<sn>
<phase>
<lim_set>
<all>
<lim_query>
Remarks
You can use <all> to query the phases of all orders of the harmonic.
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
If querying the specified harmonic component, the query returns the phase of the
specified order of combine harmonic, for example, 10.000000. If querying the phases
DG800 Pro/DG900 Pro Programming
Guide
120
n >]]:HARMonic:COMBine:PHASe < sn >,{< phase >|< lim_set >}
n >]]:HARMonic:COMBine:PHASe? {< sn >|< all >}[,< lim_query >]
Type
Range
Discrete
{1|2}
Integer
2 to 20
Real
0° to 360°
Discrete
{MINimum|MAXimum|DEFault}
Discrete
{ALL}
Discrete
{MINimum|MAXimum}