Source[<N>]]:Function:pulse:period - Rigol DG800 Pro Series Programming Manual

Function/arbitrary waveform generator
Hide thumbs Also See for DG800 Pro Series:
Table of Contents

Advertisement

Name
<percent>
<lim_set>
<lim_query>
Remarks
The pulse duty cycle is defined as the percentage of the pulse width
[:SOURce[<n>]]:FUNCtion:PULSe:WIDTh
(
[:SOURce[<n>]]:FUNCtion:PULSe:PERiod
(
When [:SOURce[<n>]] or [<n>] is omitted, it is interpreted as CH1.
Return Format
The query returns the pulse duty cycle in scientific notation. For example, the query
might return +4.500000000000000E+01, indicating that the pulse duty cycle is 45%.
Examples
:SOURce1:FUNCtion:PULSe:DCYCle 45 /*Sets the pulse duty cycle to
45% for CH1.*/
:SOURce1:FUNCtion:PULSe:DCYCle? /*Queries the pulse duty cycle for
CH1. The query returns +4.500000000000000E+01.*/
3.11.8.4
[:SOURce[<n>]]:FUNCtion:PULSe:PERiod
Syntax
[:SOURce[<
[:SOURce[<
Description
Sets or queries the pulse period for the specified channel.
Parameter
Name
<n>
<seconds>
<lim_set>
<lim_query>
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
Type
Range
Real
0.01% to 99.99%
Discrete
{MINimum|MAXimum|DEFault}
Discrete
{MINimum|MAXimum}
n >]]:FUNCtion:PULSe:PERiod {< seconds >|< lim_set >}
n >]]:FUNCtion:PULSe:PERiod?[< lim_query >]
Type
Range
Discrete
{1|2}
Real
Refer to
Discrete
{MAXimum|MINimum|DEFault}
Discrete
{MAXimum|MINimum}
) to the pulse period
).
Remarks
DG800 Pro/DG900 Pro Programming
Command System
Default
50%
-
-
Default
1
1 ms
-
-
Guide
105

Advertisement

Table of Contents
loading

Table of Contents